as follows if you wish to enable the function: make sure you have enabled
extended Menu 1, use the select key to select blinking LED L1 and then
press the SET key; at the same time LED L1 will become steady on and
programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
2. PED MOT. T. (Programming of pedestrian opening motor time of
max 4 minutes):
The control unit is factory set with Motor Time (Pedestrian opening) of 10
seconds without any deceleration.
If the pedestrian motor time must be changed, programming must be
carried out with the gate closed as follows: ensure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L2 and
then press the SET key momentarily. The Operator will start the Opening
cycle; when the gate reaches the desired initial deceleration position press
the SET key again: LED L2 will start blinking more slowly and the Operator
performs the deceleration; when the desired position is reached press the
SET key to terminate the Opening cycle. At this point LED L2 returns to the
normal blinking speed and the Operator restarts in the Closing movement;
repeat the operations described above for the Closing movement.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycle has been completed
press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand
3. DECELERATION:
As indicated above, the control unit allows a deceleration stage to be
programmed during opening and closing, while with the Automatic
Programming function the deceleration stage is included automatically.
However, if no deceleration is required, this stage can be inhibited. In this
manner, when using Automatic Programming the Deceleration stage will
no longer be included, while if the Operator Times Programming function
is used the option of specifying a deceleration stage during opening and
closing will no longer be available. If, before excluding the deceleration
stage it had already been programmed using the Operator Times
Programming function, programming must be repeated from the beginning.
If the deceleration stage is to be excluded proceed as follows: make
sure you have enabled Extended Menu 1, use the SELECT key to select
blinking LED L3 and then press the SET key: LED L3 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous configuration.
4. REMOTE CODE PGM (Remote Programming of Radio remote
controls):
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SELECT key.
Remote programming of a Radio remote control is performed as follows:
send, continuously for a time in excess of 10 seconds, the code of a
previously saved remote; at the same time the control unit switches
to programming mode as described above for the CODE LED in the
main menu. If a pedestrian code previously stored in the control unit is
transmitted continuously, the control unit switches to programming of a
new pedestrian code. The control unit is factory set with transmission code
remote programming disabled; proceed as follows if you wish to enable the
function: make sure you have enabled extended Menu 1, use the SELECT
key to select blinking LED L4 and then press the SET key; at the same time
LED L4 will become steady on and programming will be completed. Repeat
the procedure if you wish to restore the previous configuration.
5. RELEASE STROKE:
The control unit is factory set with the Release Stroke function disabled. To
enable the Release Stroke function at maximum power, proceed as follows:
make sure you have enabled Extended Menu 1, use the SELECT key to
select blinking LED L5 then press the SET key, LED L5 becomes steady on
and the programming procedure will be completed. If you wish to enable
the Release Stroke function at the power set with the "FORCE" trimmer,
repeat the procedure described above, press the SELECT key twice (LED
L5 will blink rapidly) rather than just once. Repeat the procedure if you wish
to restore the initial configuration.
This procedure makes it possible to facilitate release of the gate lock and
thus allow correct execution of the opening stroke. With this function, before
starting the opening stroke the control unit sends a closing command for 2
seconds with the thrust force associated with the selection made.
6. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the presence of a deceleration stage during
closing, 1 extra second at the maximum power or at the power selected
with the "FORCE" trimmer, in such a way as to ensure positive engagement
of the gate lock, if installed. If you wish to enable the Slam Lock function
at maximum power, proceed as follows: make sure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L6 and then
press the SET key: LED L6 becomes steady on and programming will be
completed. If you wish to enable the Slam Lock function at the power set
with the "FORCE" Trimmer, repeat the operation described by pressing the
SELECT key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial configuration.
7. PREFLASHING/COURTESY LIGHT:
The control unit is factory set with the Preflashing and Courtesy Light
functions disabled. If you wish to enable the Preflashing function proceed
as follows: make sure you have enabled Extended Menu 1, use the SEL key
to select blinking LED L7 and then press the SET key: the LED becomes
steady on and programming will be completed. If you wish to enable the
Courtesy Light function, repeat the operation described above, pressing
the SET key twice (the LED will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial configuration.
Preflashing Operation: The 24 V~ 4W max. Flashing Light output will
always switch on 3 seconds before the gate starts the closing operation.
Courtesy Light Operation: The 24 V~ 4W max. Courtesy Light output
will switch on for 3 minutes whenever an opening command is transmitted
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 2, proceed as follows: select blinking LED no. 8 and press SET
twice. The LED will start blinking alternately 1 1 0 1 1 0 1 1 0. This means
there is a period of 30 seconds to select the functions in Extended Menu 2
using the SELECT and SET keys and then, after a further 30 seconds, the
control unit will revert to the main menu.
L1
SOFT STOP
L2
SOFT START
L3
DS 1 IN OPEN
L4
HOLD-TO-RUN
L5
FOLLOW ME
L6
PAUSE FLASHING
L7
ALWAYS CLOSE
LEV
MENU
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L1
and press the SET key; at the same time LED L1 becomes steady on and
programming will be completed. With this function enabled at the end of the
movement the control unit will reduce operator force to zero gradually in a
2 second interval. Repeat the procedure if you wish to restore the previous
configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L2
and press the SET key; at the same time LED L2 becomes steady on
and programming will be completed. With this function enabled at the start
of each movement the control unit will regulate start-up of the operator,
gradually increasing the force from the minimum to the value set by the
"FORCE" trimmer during the first 2 seconds of operation. Repeat the
procedure if you wish to restore the previous configuration.
Note: when the Soft Start function is enabled the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled then
Starting Torque is automatically enabled.
3. DS 1 also in opening:
The control unit allows the operation of input DS1 to be modified. If you
want DS 1 to operate also during opening (momentary stopping of the
gate, as soon as the photocell is freed the control unit resumes the opening
movement), proceed as follows: ensure you have enabled Extended Menu
2 and then press the SEL key to select blinking LED L3 and press the SET
key: LED L3 becomes steady on and programming will be completed.
COMUNELLO ®Copyright 2014 - All right reserved
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 FLASHES
17