Troubleshooting Ro Dd60 - Rothenberger RO DD60 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
If performance diminishes, recharge the battery pack.
The ideal storage temperature is between 10° C and 30° C. The permissible storage temperature
is between 0° C and 50° C.
"Li-Power" li-ion battery packs have a capacity and signal indicator: (6)
Press the button (5), the LEDs indicate the charge level.
If one LED is flashing, the battery pack is almost flat and must be recharged.
Handling
Charging battery pack:
Push the battery pack completely to the stop on the sliding seat (2).
The operating indicator (3) flashes.
Conservation charge:
Once the charging process has finished, the battery charger automatically switches to conserva-
tion mode.
The battery pack can remain in the battery charger and is therefore always ready for use.
The operating display (3) lights up continuously.
Fault:
● Warning display (4) lights up continuously.
Battery pack is not charged. Temperature too high/ too low. When the temperature of the battery
pack is between 0 ° C and 50 ° C, the charging process begins automatically.
● Warning display (4) flashes.
Battery pack is defective. Remove the battery pack immediately from the charger.
The battery pack was not pushed correctly onto the sliding seat (2).
5

Troubleshooting RO DD60

The machine's multifunctional monitoring system:
If the machine switches off automatically, the machine electronics have activated
automatic protection mode. A warning signal sounds (continuous beeping). The
beeping stops after a maximum of 30 seconds or when the trigger (10) is released.
In spite of this protective function, overloading is still possible with certain applica-
tions and can result in damage to the machine.
Causes and remedies:
Long continuous overloading of the machine will activate the temperature cut-out. Leave the
machine or battery pack to cool.
Note: If the battery pack feels very warm, the pack will cool more quickly in an "AIR COOLED"
charger.
Note: The machine will cool more quickly if you operate it at idling speed.
Safety shutdown: The machine was SWITCHED OFF automatically. If the slew rate of the cur-
rent is too high (for example, if the machine suddenly seizes or kickback occurs), the machine
switches off. Switch off the machine at the trigger (10). Switch it on again and continue to work
as normal. Try to prevent the machine from seizing.
Switch off the machine at the trigger (10). Then continue working as normal. Try to prevent the
machine from seizing.
ENGLISH
19

Publicidad

Tabla de contenido
loading

Tabla de contenido