The conductor diameter of the power cable should not be smaller than the values given in the table
below.
Model
DLU-211, 311, 411, 511
DHU-211, 311, 411 ,511
The power switch should be connected directly to the power terminal (electric cabinet), while
making it possible to safely and reliably disconnect all phases powering the device. When the circuit is
broken, the gap between the jumpers of the switch should not be smaller than 3mm.
After installation, the device must be checked for leakage conductance. The value of leakage
conductance per 1kW of the power of the device should be lower than 1mA.
WARNING!!!
If an equipotential bonding bar is required, its connections must be checked.
2.2 TRANSPORT, LIFTING, UNPACKING, STORAGE.
Correct and safe transport:
• use equipment appropriate for the weight and structure of the devices;
• cover corners and sharp edges;
Before carrying:
• secure the area against unauthorised personnel;
• make sure that the load is properly secured;
• check all loose components lest they should fall when being lifted;
• try to lift the load as vertically as possible so as not to make any dents in it;
• while carrying the load, make sure that it is as near the ground as possible.
2.3 INTENDED USE AND LIMITATIONS.
Top extensions are designed to enhance the hygiene and aesthetics of the drinks and products
displayed (lighting top extension), and for displaying and keeping dishes warm under halogen heating
lamps (heating top extensions) before they are served.
Before starting to use the top extensions, check the electrical system for efficiency and
reliability.
After work, set the power switch (C) to zero (Figure 1).
3
edenox.com
Designation of the power cable
(type, number of conductors, cross-section area of conductors)
PCG 3 x 1.5 mm
ENGLISH
2