Installation Procedures

This manual does not cover all user cases; please contact
places to propose new requirements and clear new doubts and problems.
Standard installation tools are recommended according to installation requirements.
For information about standard model series accessories, see packing list; other necessary parts
to be installed shall be prepared by users as required by installation service network stations.
Decide upon places to install the indoor unit; places where even circulation of cool
and warm air can be delivered shall be selected; and places below shall be avoided:
Places (in coastal areas) where salinity is high; where sulfurized gases are usual (areas where
springs flourish and copper tube and braze easily get corroded); where oils (machinery oils)
and steam are usual; where organic solvents are put to use; where machines radiating high
frequency electromagnetic waves exist (which cause control system malfunctions); where
contact with humid air near windows and doors is pervasive (making for easy condensation)
and; where special sprayers are put to frequent use.

Installing Indoor Unit

1. The distance from air outlet to floor surface shall not exceed 2.7m.
2. Make sure that outlet airflow covers the whole room area; and arrange connecting tubes, wires
and drain pipes to proper outdoor positions.
3. Make sure that ceiling structures are capable of bearing unit weight.
4. Connecting tubes, drain pipes and connecting wires can be put across walls to connect indoor
unit and outdoor unit.
5. Connecting tubes and drain pipes between indoor and outdoor units shall be shorter for better.
6. Please refer to outdoor installation manual when refrigerant charging volume adjusting is
necessary.
7. Joint flanges shall be prepared by users.
8. Valuables (e.g., TV sets, instruments, equipments, artworks, pianos, wireless devices) shall
not be placed below the indoor unit lest condensed water drips upon the same.
Installing and Fixing
1. Drilling Wall Holes
Drill a wall hole (dia.70mm, see figure 1), slightly tilted
downwards on the outside; fix guard ring to finalize
before sealing the wall hole with gesso or putty.
2. Preparation prior to Installing Indoor Unit
Open inlet grille according to figure 2.
Figure 2 Model FAV012, FAV024
Airwell
Indoor Side
Wall Hole
70mm
Figure 1 (Wall Hole in Section)
20
marketing centers in local
Outdoor Side
Wall Thickness