SPACERS
Behind the machine there are 2 spacers that delimit the minimum distance between the stove and anything behind it.
The spacers must not be removed.
Note: direct the room probe downwards or outwards of the stove.
HOT AIR DUCTING
The hot air ducting pipe must have an internal diameter of 80 mm, it must be insulated or at least protected from heat dispersion.
Characteristics:
rear or lateral output
ducting output diameter: 80 mm
maximum recommended ducting length 8 m
ADDITIONAL THERMOSTAT TO CONTROL THE DUCT MOTOR
For models with duct motor, it is also possible to thermostat the motor itself. The connection to an external thermostat will allow for the
duct motor to be controlled regardless of stove operation.
At this point, simply set the desired temperature on the thermostat; the thermostat will command
the operation of the second motor:
when the temperature has not been reached (contact closed) the second motor will follow the
operation of the stove.
when the temperature has been reached (contact open), the motor will turn o and the duct
motor LED will ash.
The duct thermostat terminal features a standard bridge.
See drawing to the side.
possibility to thermostat the ducting
possibility to adjust the fan speed percentage.