IGNITION
After checking the previous points, press the 1 for three seconds to switch on the stove. For the ignition phase, 15 minutes are available during
which the presence of the ame is checked. When the control temperature has been reached, the stove stops the ignition phase and goes into
PREPARATION.
PREPARATION
During the preparation phase, the stove stabilises and gradually increases combustion, and then activates the ventilation and goes into WORK
WORK
During the work phase, the stove reaches the Set Power de ned by the user, heating the room until the Set Thermostat has been reached. See
following note.
SET THERMOSTAT
The Set room thermostat can be set using keys 4 and 5, from LOW TA - 7°C - 37°C - HOT. If the value is between 7°C - 37°C, the stove checks
the room temperature using a probe on the machine. Once the set temperature has been reached, the stove automatically reduces the power
ensuring optimal comfort and reducing the consumption of pellets: this process is called "modulation".
LOW TA / HOT
If the Set Thermostat is "LOW TA" (set below the 7° threshold) the temperature is checked by the additional thermostat contact, thus ignoring
the temperature probe on the machine.
If the contact is closed (required), the stove operates at the set power.
If the contact is open (met), the stove operates at the minimum value.
If the setting is on "HOT" (set above 37°C) the stove always operates at the set power, ignoring the external contact and the temperature probe.
SET POWER
The Set Power ha 5 levels of operation. The power can be changed using keys 2 or 3.
Power 1 = minimum level - Power 5 = maximum level.
The change is saved after exiting by pressing 1.
AUTO BLOW
During the work phase and at regular time intervals, the stove cleans the burn pot by means of an operation called "AUTO BLOW".
The activation of this function is shown on the display with the relative message. During the "AUTO BLOW" the pellet loading is slowed down
and the fumes motor is increased.
After the cleaning phase, the stove goes back to the normal operating conditions.
SWITCH OFF
Press 1 for three seconds.
After performing this operation, the appliance automatically enters the switch-o phase, and stops loading pellets.
The fumes motor and the hot air fan motor remain on until the stove temperature falls below the safety threshold.
RE IGNITION
The stove can be switched back on only if the fume temperature is lower than a preset threshold and if a minimum safety time has elapsed.
NEVER USE FLAMMABLE LIQUIDS FOR IGNITION!
WHILE FILLING, DO NOT BRING THE PELLET BAG IN CONTACT WITH THE BOILING STOVE!
IN CASE OF CONTINUOUS FAILED IGNITIONS, CONTACT AN AUTHORISED TECHNICIAN.
DO NOT USE THE APPLIANCE WITHOUT THE SEPARATOR AND/OR FLAME
GUARD SEE FIGURE TO THE SIDE . REMOVING THEM WILL AFFECT THE SAFETY
OF THE PRODUCT AND WILL INVALIDATE THE WARRANTY IMMEDIATELY. IN
THE EVENT OF WEAR OR DETERIORATION, REQUEST THE REPLACEMENT OF
THE PART FROM THE SERVICE CENTRE THIS TYPE OF REPLACEMENT IS NOT
COVERED BY WARRANTY BECAUSE IT IS A COMPONENT SUBJECT TO WEAR .
ENGLISH
Upper BURN POT PARTITION
53