Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Remove the knob unit (B).
3 - Undo the screws (C) and remove the control
panel (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a flexible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80° C.
Important
When connecting, take care to connect the
neutral and earth lines.
TESTING OF THE APPLIANCE
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
IT
requirements have been complied with in
full.
GB
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
DE
that of the appliance.
FR
ES
RECOMMENDATIONS FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed. In particular,
turn off the water supply tap, cut off the
English
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
ADJUSTMENTS
electricity supply using the master switch
and prevent access to all devices that
might cause unexpected health and safety
hazards if turned on.
- 18 -
A
C
B
D
C
5 - Replace the control panel (C) and the knobs (B)
on completion of the operation.
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Check that the safety device is operating cor-
rectly.
E
IDM-39616401400.tif
8