3.2 Unlocking access to programming
1. Scroll through the parameters with the buttons
and
until the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the unlocking
code;
4. Within 10 sec. press the CH1 of the "TX Master",
the display shows
to the list of parameters;
5. Access to programming is unlocked.
3.3 Unlocking access to programming and global reset
WARNING!
This procedure involves the loss of all stored set-
tings.
The procedure allows the unlocking of the control panel without
having to know its unlocking code.
Following this release, you must program the control panel again
and adjust all operating parameters, in particular, remember to
properly set the confi guration of parameters (P028 - P029 -
P030 – operator confi guration). You will also need to repeat the
measurement of impact forces to ensure the installation compli-
ance to standards.
1. Scroll through the parameters with the buttons
the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
4. Press the button
, the display shows the fl ashing writing
;
5. Press the button again and hold for 5 seconds (releasing it be-
fore, the procedure is terminated): The display shows the fi xed
writing
followed by
parameters;
6. Access to programming is unlocked.
4 Inputs confi guration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can confi gure each input for the
operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the
to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confi rm by pressing on the
P018);
3. Scroll down with the
the desired operation (refer to table "Input Confi guration parameters" on
page 33);
4. Confi rm by pressing on the
5. Execute the new connection to the input just reconfi gured.
5 Programming complete
WARNING At the end of the programming procedure, use the buttons
is now ready again for new manoeuvres.
30
;
before returning
and
;
;
, before returning to the list of
and
to see that corresponding
key to get access to the parameter (eg.
and
, keys to set the value corresponding to
key (display shows again P018).
until