Assembly - Standard Ceiling Mount
1
Preparing for mounting
Remove the canopy ring (L) from the canopy (C) by turning
the ring counterclockwise until it unlocks.
Remove the mounting bracket (A) from the canopy (C) by
loosening the two canopy screws (CC) located in the "L
shaped" slots.
Remove and save the two canopy screws (DD) in the round
holes. This will enable you to remove the mounting bracket
(A).
CC
3
Assembling the fan
CAUTION: To ensure wobble-free operation and to avoid
damage to the fan, the downrod (B) and the setscrew
(EE) must be completely tightened
NOTE: This fan is equipped with a safety tab (FF). Should
the setscrew (EE) ever become loose while the fan is
running in reverse, the safety tab (FF) will engage and
stop the fan from falling.
Loosen, but do not remove, the setscrew (EE) on the motor
collar (M) on top of the fan motor assembly (E) by turning it
counterclockwise.
Install the downrod (B) by inserting it into the motor collar (M),
and turning it clockwise until it is tight.
Re-tighten the setscrew, (EE) on the motor collar (M) on top of
the fan motor assembly (E), by turning it clockwise.
2
A
DD
C
L
7
Routing the wires
Route the wires exiting the top of the fan-motor
assembly (E) through the center of the canopy ring (L).
Insert the ball/downrod (B) through the canopy (C) and
slide the decorative motor collar cover (D) onto the end
of the ball/downrod (B). Make sure the slots on the
canopy (C) are on top.
Route the wires exiting the top of the fan motor
assembly (E) through the downrod as shown.
EE
HOMEDEPOT.COM/HOMEDECORATORS
Please contact 1-800-986-3460 for further assistance.
C
L
D
B
E
B