OPERATION

POWER CORDS

Using Extension Cords
Westinghouse Outdoor Power Equipment assumes no responsibility for the content within this table. The use of this
table is the responsibility of the user only. This table is intended for reference only. The results produced by using this
table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly
variable. Always check with local regulations and a licensed electrician prior to installing or connecting an electrical
appliance.

INVERTER PARALLELING OPERATION

Never connect or remove the
paralleling kit to the inverters with
the inverters running. Make sure
the parallel kit cables are in good
working order. A faulty appliance or
power cord can create a potential for
electrical shock.
WARNING
Use only approved Westinghouse
parallel kit cables. Do not use the
paralleling cord for any application
other than inverter paralleling. For
single generator operation, the parallel
operation cable must be removed.
12 | Westinghouse Outdoor Power Equipment
DANGER
INVERTER PARALLELING OPERATION
Note: Most motorized appliances require more than
their electrical rating for startup. When an electric motor
is started, the overload indicator (red) may come ON.
This is normal if the overload indicator (red) goes off
within 4 seconds. If the overload indicator (red) stays
ON, consult Westinghouse service team.
1. Connect the parallel operation kit cables between
both inverters (kit and additional inverter sold
separate). The leads on the parallel kit can go in
either of the parallel operation outlets.
2. Start each inverter and make sure the output
indicator (green) on each inverter comes ON.
3. Plug appliance into the parallel operation kit outlet.
To shut down: Turn off both inverters, then remove
parallel operation cables.