IT T
Flashes
Controller Status
7 Blinks
Temperature
The controller will auto-
matically restart when the
temperature reaches an
acceptable level. If fault
persists contact installer.
8 Blinks
Open Lead
The controller will not
restart if displaying this
fault. To clear the fault, turn
off power to the controller,
wait 1 minute, turn on pow-
er to the controller. If fault
persists contact installer.
9 Blinks
Broken Pipe
The controller will not
restart if displaying this
fault. To clear the fault, turn
off power to the controller,
wait 1 minute, turn on pow-
er to the controller. If fault
persists contact installer.
This warranty applies to the Balanced Flow Series Controller manufactured by CentriPro.
Any part or parts found to be defective within the warranty period shall be replaced at no charge to the dealer during the warranty period. The warranty pe-
riod shall exist for a period of twenty-four (24) months from date of installation or thirty (30) months from date of manufacture, whichever period is shorter.
A dealer who believes that a warranty claim exists must contact the authorized CentriPro distributor from whom the equipment was purchased and furnish
complete details regarding the claim. The distributor is authorized to adjust any warranty claims utilizing the CentriPro Customer Service Department.
The warranty excludes:
(a) Labor, transportation and related costs incurred by the dealer;
(b) Reinstallation costs of repaired equipment;
(c) Reinstallation costs of replacement equipment;
For purposes of this warranty, the following terms have these definitions:
(1) "Distributor" means any individual, partnership, corporation, association, or other legal relationship that stands between CentriPro and the dealer in
purchases, consignments or contracts for sale of the subject equipment.
(2) "Dealer" means any individual, partnership, corporation, association, or other legal relationship which engages in the business of selling or leasing equip-
ment to customers.
(3) "Customer" means any entity who buys or leases the subject equipment from a dealer. The "customer" may mean an individual, partnership, corporation,
limited liability company, association or other legal entity which may engage in any type of business.
CentriPro
CentriPro and the ITT Engineered Blocks Symbol are
registered trademarks and tradenames of ITT Corporation.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Residential & Commercial Water Systems
RED LIGHT CODES
Description
This fault can be caused by:
• High ambient temperature. The maximum ambient temperature
rating is 122º F (50º C).
• Low ambient temperature. The minimum ambient temperature
rating is -4º F (-20º C).
Check for a fan failure. The fan will turn on when the temperature
inside the controller reaches 140º F (60º C). The fan will turn on for
1 second each time the controller starts the motor. If the fan never
turns on, check fan connections and replace as needed. Ensure that
the external fan intake filter is not blocked or clogged. It can be
removed for cleaning and replacements are available.
This fault can be caused by:
• Disconnected or broken wire between the controller and motor.
Verify the error by turning power to controller off for 1 minute and
then on. If error persists, motor and wiring between controller and
motor must be checked. Turn power off for 5 minutes. Remove the
three motor wires from the terminal block. Using an ohmmeter,
measure the resistance from phase to phase. A disconnected or
broken wire will be indicated by a high resistance reading (20 ohms
or higher).
This fault can be caused by:
• Pressure 20 PSI below set point for 30 seconds. May be a broken
pipe or tripped pressure relief valve. If 20 PSI or more pressure
drop for 30 seconds is normal for the system, switch the broken
pipe protection off or change system to prevent the pressure drop.
Table 6: Fault Blink Codes
CENTRIPRO LIMITED WARRANTY
THIS WARRANTY EXTENDS TO THE DEALER ONLY.
®
(continued from previous page)
(d)
Consequential damages of any kind; and,
(e)
Reimbursement for loss caused by interruption of service.
IM182 Revision 12