5.10 SPARK PLUG
The spark plug(s) must be replaced every 200
hours of operation (=at every other basic service).
Use the spark plug key supplied.
Before disconnecting the spark plug, clean around
its mounting.
Spark plug: Champion RC12YC or equivalent..
Electrode distance: 0.75 mm.
5.11 AIR INTAKE (7:P)
The engine is air-cooled. A blocked cooling sys-
tem can damage the engine. Clean the engine's air
intake after 50 hours of operation. More meticu-
lous cleaning of the cooling system is carried out
during each basic service.
5.12 LUBRICATION
All lubrication points in accordance with the table
below must be lubricated every 25 hours of opera-
tion as well as after every wash.
Object
Action
Rear shaft
3 grease nipples. (13:V)
Use a grease gun filled with
universal grease. Pump until
the grease emerges.
Steering
Brush the cables clean with a
cables
wire brush.
Lubricate with universal
chain spray.
Tensioning
Lubricate the bearing points
arms
with an oil can when each
control is activated.
Ideally carried out by two
people.
Control
Lubricate the cable ends with
cables
an oil can when each control
is activated.
Must be carried out by two
people.
5.13 FUSE
In the event of electrical faults, check/replace the
fuse, 20 A. See fig. 20.
If the fault persists, contact an authorised work-
shop for repair.
The fuse is located together with the battery under
the engine casing.
ENGLISH
6 PATENT - DESIGN REGISTRA-
This machine or parts thereof is covered by the fol-
lowing patent and design registration:
9900627-2 (SE), SE00/00250 (PCT), 9901091-0
(SE), SE00/00577 (PCT), 9901730-3 (SE), SE00/
00895 (PCT), 9401745-6 (SE), SE95/00525
(PCT), 595 7497 (US), 95920332.4 (EPC).
99 1095 (SE), 499 11 740.9 (DE), M1990 000734
(IT), 577 251-253 (FR), 115325 (US).
Figure
13
-
14
15
GGP reserves the right to make alterations to the
product without prior notification.
TION
EN
47