Scope Of This Manual; Model Identification; Typical Application Examples; Application Examples With Only 1 Heat Emitter - Rotex RKHBRD011ABV1 Manual De Instalación

Unidad interior para bomba de calor de aire-agua
Ocultar thumbs Ver también para RKHBRD011ABV1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 223
Remote controller (option)
An optional secondary RKRUAHTA remote controller (with room
thermostat functionality) can be connected to the indoor unit.
Purpose is to provide the possibility to install the standard remote
controller near the unit (for service reasons), and install another
remote controller in another place (e.g. living room) to operate your
installation.
Refer to the "Installation of the remote controller" on page 17 for
further details.
Room thermostat (option)
An optional room thermostat RKRTR or RKRTW can be connected to
the indoor unit.
Refer to the room thermostat installation manual for further details.
If this option is installed it is not possible to use the remote
controller thermostat function.
Heater kit (option)
An optional RKBUH heater kit can be combined with the indoor unit.
Purpose is to provide an additional heating capacity during cold
outdoor temperatures. The heater kit has a heating capacity of 6 kW,
and available for both 1-phase and 3-phase power supply
specifications. When using this heater kit, installation of the optional
demand PCB is required as well.
Refer to the heater kit installation manual for further details.
P
H
2
3
1
1
Heat pump capacity
2
Required heating capacity (site dependent)
3
Additional heating capacity provided by the heater kit
T
Ambient (outdoor) temperature
A
P
Heating capacity
H
Digital I/O PCB (option)
An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs.
Refer to the operation manual of the indoor unit and to the digital I/O
PCB installation manual for more information.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.
Demand PCB (option)
An optional EKRP1AHTA demand PCB can be connected to the
indoor unit. This PCB is needed when the optional heater kit RKBUH
or Rotex room thermostat RKRTR or RKRTW is installed or when
multiple set point control is used, and provides the communication
with the indoor unit.
Refer to the demand PCB installation manual for further details.
Refer to the wiring diagram or connection diagram for connecting this
PCB to the unit.
RKHBRD011~016ABV1+Y1
Indoor unit for air to water heat pump system
4PW61218-1C – 2012.06

Scope of this manual

This installation manual describes the procedures for handling,
installing and connecting all RKHBRD indoor unit models.
NOTE
Model identification
Indoor unit
RK
(a) For exact values, refer to "Unit specifications" on page 38.

Typical application examples

The application examples given below are for illustration purposes
only.
Application examples with only 1 heat emitter and 1
heat source (RKHBRD unit)
If only 1 heat emitter (= all system has 1 water set point), it is
recommended NOT to use a balancing bottle.
Using a balancing bottle will affect the optimal pump control of the
unit and will increase the cost of the system unnecessarily.
Application 1
Space heating and domestic hot water heating with a single
T
A
remote controller installed in the living room.
Installation of the RRRQ heat pump outdoor is
described in the outdoor unit installation manual.
Operation of the indoor unit is described in the indoor
unit operation manual.
HBR
D
016
AB
V1
Series
Indication of heating capacity (kW)
Refrigerant type R134a
Hydro box - high temperature heating only
Rotex kit
1
12
2
3
12
4
6
M
5
8
1
Outdoor unit
2
Indoor unit
3
Refrigerant heat
exchanger
4
Water heat exchanger
5
Compressor
6
Pump
7
Shut-off valve
8
Motorized 3-way valve
(optional)
V1 = 1N~, 220-240 V, 50 Hz
Y1 = 3N~, 380-415 V, 50 Hz
(a)
A
B
C1
7 10 13
11
9
9
Domestic hot water
tank (optional)
10
Collector (field supply)
11
Radiator (field supply)
12
Electronic expansion
valve
13
By-pass valve (field
supply)
C1
Remote controller
A
Installation place
B
Living room
Installation manual
2