DNCKE−...−S / KEC−...−S
5.1.2
Mount attachment components
Mounting on the DNCKE
Mount the attachment component to the piston rod.
The spanner flat aJ on the piston rod serves as a counter holder
for the lock nut. If necessary, secure the lock nut with a screw
locking agent.
5.1.3
Mounting accessories
If proximity switches are used in the cylinder with clamping unit
DNCKE:
Use proximity sensors from the Festo accessories
(è www.festo.com/catalogue).
Place the proximity switches in the slots 8 of the cylinder.
Tighten the proximity switches in the desired switching positions.
5.2
Pneumatic installation
5.2.1
Prerequisites
Check whether the following accessories are required:
Description
Check valve
Compensation reservoir VZS
Tab. 3
Use a one-way flow control valve type (e.g. GRLZ or GRLA) directly at the respective compressed air
supply port.
Festo – DNCKE−...−S / KEC−...−S – 1511b English
Type
HGL
Fig. 7
Fig. 8
Function
Slows pressure reduction when compressed air
is lost
Redundancy with "stop function"
Reduction of pressure fluctuations in the following
compressed air string
aJ
8
37