DNCKE−...−S / KEC−...−S
13
Technical data
Size
Clamping type
Mounting position
Operating medium
Operating pressure
Clamping unit
Cylinder
Max. test pressure
Round material
Diameter
Quality
Static and dynamic holding force
Theoretical force
Advance at 6 bar
Return at 6 bar
Advance at max. test pressure
Return at max. test pressure
Max. permissible travel speed
Ambient temperature
Storage temperature
Vibration and shock (without payload)
Vibration in accordance with
IEC 60068 part 2-6
Shock in accordance with
IEC 60068 part 2-27
Continuous shock in accordance
with IEC 60068 part 2-29
52
DNCKE
40
KEC
16
Clamping through spring force, releasing through
compressed air
any
Compressed air in accordance with ISO 8573-1-2010
[7:4:4]; operation with lubricated medium possible (in
which case lubricated operation will always be
required)
[bar]
3.8 ... 8
DNCKE
[bar]
0.6 ... 8
DNCKE
[bar]
10
[mm]
16 [h7 ... f7]
Hardened (min. HRC 60) or
hard chrome-plated (thickness of layer min. 20 ìm)
Surface roughness Rt less than 4 ìm
3 mm wide 15° chamfer on the end of the round
material
[N]
1300
DNCKE
[N]
754
[N]
633
[N]
1257
[N]
1055
[m/s]
1
[°C]
–10 ... +60
[°C]
–20 ... +80
± 3.5 mm deflection at 2-8 Hz
10 m/s
± 0.35 mm deflection at 27-60 Hz
50 m/s
10 m/s
± 300 m/s
5 shocks per direction
± 150 m/s
1000 shocks per direction
63
20
20 [h7 ... f7]
3200
1870
1682
3117
2803
2
acceleration at 8-27 Hz
2
acceleration at 60-160 Hz
2
acceleration at 160-200 Hz
2
acceleration with 11 ms duration
2
acceleration at 6 ms duration
Festo – DNCKE−...−S / KEC−...−S – 1511b English
100
25
25 [h7 ... f7]
8000
4712
4418
7854
7363