Installation; Regulations; Mounting To Wall Pag; Room Ventilation - Beretta Fonte 11 AE Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
Product datasheet - Description
Water heating energy efficiency class
Declared load profile
Water heating energy efficiency class
Daily fuel consumption
Annual fuel consumption
Indoor sound power level
Nitrogen oxide emissions
Fig.2
1
Flue gas release safety device
2
Release hood
3
Heat exchanger
4
Ignition electrode
5
Burner
6
Hydraulic valve
7
Temperature regulator
8
Gas valve
9
Gas input
10
Gas adjustment screws
11
Electronic devices
12
Battery box
13
Economiser
14
Gas pressure intake
15
Pilot burner

2. INSTALLATION

2.a Regulations (Fig.3)
The use of gas devices is controlled by precise regulations. It is
essential to observe regulations in force.
Installation of liquid petroleum gas (L.P.G) must comply with all the
distributor's requirements and those of the regulations.
2.b Wall mounting (Fig.4)
Warning
Do not install this device in an area that contains dust, greasy
vapour and/or corrosive elements.
- The device must be installed on a suitable wall surface in proximi-
ty to a fume disposal flue.
- It is vital to leave the minimal distances around the device as
shown in fig 3 to allow for maintenance operations to take place.
Location
The water heater must not be tightly placed in an enclosure or
slot, it should have an adequate flow of air around it (fig. 4)
- The water heater must not be placed above a kitchen or other
cooking devices that might deposit grease vapour on its exterior
leading to corrosion
- surfaces that sensitive to heat (e.g. wood) must be protected
using appropriate insulation.
- Fig. 4 displays the dimensions necessary for wall mounting
11
C
244
E
605
F
150
2.c Room ventilation
The installation of the water heater must comply with regulations in
force including any updates. See paragraph 2.a
Warning: This device can only be installed in venues that are per-
manently ventilated according to regulation in force.
Air circulation
It is vital that areas where gas devices are installed (type B) have
access to the amount of air necessary for the regular combustion of
gas as well as the ventilation of the venue.
-
-
ηwh
Qfuel
AFC
LWA
NOx
14
274
640
155
Fonte 11 AE
A
M
73,8
8,542
6
56
114
- It is prohibited to use an extractor fan, fireplaces and other similar
devices at the same time as the water heater
- The area where the water heater is installed must have a regular
flow of air for ventilation.
Air flow
The flow of air must occur by the following means:
- Permanent openings in the wall that lead outdoors;
- Single or collective ventilation ducts.
The air used for ventilation must be taken directly from an outside
location, that is far from sources of pollution.
Indirect ventilation from adjacent areas are permitted with the fol-
lowing limitations:
- the adjacent area is equipped with direct ventilation;
- the devices within the area to ventilate are connected to a waste
duct;
- the adjacent area does not contain a bedroom and is not a com-
mon area;
- the adjacent area is not a fire hazard such as a storage area for
flammable materials, garage etc.
- the adjacent area is not lower than the area to ventilate as this
might lead to an opposing draught (this can be caused by other
devices that operate on the basis of combustion, a fireplace or
any suction device that have not been given an adequate air sup-
ply);
- The air flow from the adjacent area occurs freely through perma-
nent openings.
2.d Electrical connection to battery
The device is powered by a 1.5 V battery, alkaline long lasting mo-
del LR20, thus it is not necessary to connect the device to a power
socket.
CARD CONNECTION (Fig.5)
GN3
Earth
SV2
Burner solenoid valve
SV1
Pilot solenoid valve
SW
Micro water contact
NC
Not utilized
V+
Positive feed
GN2
Negative feed
GN1
Micro water contact
T.L.
Water limit thermostat
T.F.
Flue gas thermostat
M.S.
Micro water
B
Battery box
nero
black
verde
green
arancione orange
marrone brown
rosso
red
2.e Gas Connection
See paragraph 2.a
Determine the pipe diameter according to current regulations. Befo-
re installing the device blow in the gas pipe to eliminate any residue
from its manufacturing. Connect the water heater to the internal
system's gas pipes and place a tap above the device for the halting
and release of gas.
The water heaters that are powered by tanks of L.P.G. gas with re-
gulation and interception devices, must be connected correctly so to
guarantee the safety of persons and the surrounding area.
Follow all related regulations.
11
FONTE 11-14 AE
Fonte 14 AE
A
-
L
-
76,9
%
16,214
kWh
12
GJ
58
dB(A)
120
mg/kWh

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fonte 14 ae

Tabla de contenido