HL 2020 E
Technical Specifications HL 2020 E
Item No. 110025597
Temperature 120°F - 1150°F (49°C - 621°C)
Airflow 4 / 4-8 / 6-13 cfm (+/- 0.5)
3 Stage Switch Cool air stage 120°F / 4 cfm
Variable temperature 4-8 cfm
Variable temperature 6-13 cfm
Output 1600 watts
Voltage 120 VAC / 60 Hz
Amps 13.3
Power Cord Industrial grade rubber, length: 6 ft
Nozzle Diameter 1.30" (33.02 mm)
Dimensions 9.96" x 3.37" x 7.87" (l x w x h)
Net Weight 2.19 Ibs (35.10 oz)
Single Sell Pack Dimensions: 10.20" x 3.54" x 9.33"
Weight: 2.60 Ibs (41.66 oz)
Warranty One year limited
The tool is switched on and off at the three-stage switch on the back of the grip handle. In addition to three-
stage speed/airflow control, temperature can be continuously adjusted over a range of 120 °F to 1150 °F in
settings 2 and 3 at the toggle. The tool is factory set to display the temperature in °F. The target temperature
can be increased in 10 °F steps by pressing the right-hand "+" side of the toggle or reduced in 10 °F steps
by pressing the left-hand "–" side of the toggle. Pressing the toggle briefly increases or reduces the target
temperature by one 10 °F step. Keeping the toggle pressed will continue to increase or reduce the tem-
perature in steps of 10 °F until the toggle is released or the minimum or maximum temperature is set. The
temperature setting is shown on the display for 3 seconds. On lowering or increasing the temperature, the
actual temperature at the nozzle outlet is displayed. The °C/°F symbol flashes during this period. As soon as
the selected temperature is reached, this symbol stops flashing and is displayed all the time. Blower switch
1 delivers a temperature of 120 °F. When the tool has been operating at high temperatures on blower switch
2 or 3 it will take a short while to cool to 120 °F after switching down to blower stage 1. While the tool is
cooling down, the LCD display shows the actual temperature at the nozzle outlet. After switching off, the tool
stays in the last setting that was selected. The protection tube detaches from the housing allowing accessor-
ies to be attached. Please see page 10 for the procedure to change the power cord.
English
- 8 -
HL 1920 E
Technical Specifications HL 1920 E
Item No. 110025596
Temperature 120°F - 1100°F (49°C - 593°C)
Airflow 4 / 4-8 / 6-13 cfm (+/- 0.5)
3 Stage Switch Cool air stage 120°F / 4 cfm
Variable temperature 4-8 cfm
Variable temperature 6-13 cfm
Output 1500 watts
Voltage 120 VAC / 60 Hz
Amps 12.5
Power Cord Industrial grade rubber, length: 6 ft
Nozzle Diameter 1.30" (33.02 mm)
Dimensions 9.96" x 3.33" x 7.87" (l x w x h)
Net Weight 1.9 Ibs ( 30.37 oz)
Single Sell Pack Dimensions: 10.20" x 3.54" x 9.33"
2.31 Ibs (36.93 oz)
Warranty One year limited
Thumbwheel Temperature Guide
Air flow stage II
Air flow stage III
Setting
wheel
Temperature approx.
1
80 °C / 175 °F
80 °C / 175 °F
2
100 °C / 210 °F
100 °C / 210 °F
3
180 °C / 355 °F
180 °C / 355 °F
4
270 °C / 518 °F
260 °C / 500 °F
5
330 °C / 625 °F
320 °C / 610 °F
6
410 °C / 770 °F
390 °C / 735 °F
7
480 °C / 895 °F
460 °C / 860 °F
8
560 °C / 1040 °F
530 °C / 985 °F
9
600 °C / 1100 °F
600 °C / 1100 °F
HL 1820 S
Technical Specifications HL 1820 S
Item No. 110025541
3 Stage Switch Cool air stage 120°F / 4 cfm
750 °F (399°C) / 7 cfm
1100 °F (593°C) / 13 cfm
Output 1400 watts
Voltage 120 VAC / 60 Hz
Amps 11.7
Power Cord Industrial grade rubber, length: 6 ft
Nozzle Diameter 1.30" (33.02 mm)
Dimensions 9.96" x 3.33" x 7.87" ( l x w x h)
Net Weight 1.77 Ibs (28.36 oz)
Single Sell Pack Dimensions: 10.20" x 3.54" x 9.33"
Weight: 2.18 Ibs (34.92 oz)
Warranty One year limited
The tool is switched on and off at the three-stage switch on the back of the grip handle. Air flow and temper-
ature can be adjusted to 3 settings. Stage 1 is a cool-air stage at 120 °F with an air flow rate of 4 cfm. Stage 2
reaches 750 °F at an air flow of 7 cfm, stage 3 delivers 1100 °F at 13 cfm. The protection tube detaches from
the housing allowing accessories to be attached.
English
The tool is switched on and off at the three-stage
switch on the back of the grip handle. In addition to
three-stage speed/airflow control (stage 1 is a cool-air
stage at 120 °F), temperature can be continuously
adjusted over a range of 120 °F - 1100 °F in settings
2 and 3 at the thumbwheel. The numbers 1-9 on the
thumbwheel serve as a guide only. Whereas "1" means
120 °F, the maximum temperature of 1100 °F is
attained at setting "9". Airflow can be adjusted to the
three stages of 4 / 4-8 / 6-13 cfm. The protection tube
detaches from the housing allowing accessories to be
attached.