Addition of radio controls
GB
•Before memorising a transmitter make sure that it is compatible with the type of
receiver that is integrated (the fi rst time the display shows r, if the receiver is in
rolling code mode, or f if the receiver is in fi xed code mode). The receiver can
memorise rolling codes type HCS300 STAGNOLI with billions of combinations or
fi xed codes type HT53200 with 13 bits or the fi xed part of a rolling code (28 bit
SN). It is possible to memorise up to 76 codes.
•Enter the menu
eand select the channel that is to be added. Press ENTER, the wording
(press) will appear. Press the key that must be memorised: at this point the display
shows the wording
are registration errors or
•An external antenna installed far from the ground, increases the visibility betwe-
en the transmitter and the receiver. The power of the receiver can be reduced if
metal parts or reinforced concrete are placed next to it.
Regulating
ttca
•
(automatic closing time)= this is the time from when the gate is fully open
to when it is closed automatically. If the photocell is engaged, the
counted from the time when the photocell is freed. The default time set by Stagnoli
is 10 secs and it can be regulated from 1 to 240secs.
aped
•
(pedestrian opening)= this is the length of the stroke stated in centimetres of
the partial opening, namely the pedestrian mode. The default value set by Stagno-
li is 70 and it can be regulated from 30 to 150. In case of
PEDESTRIAN opening allows the door controlled by motor 1 to open completely.
sfaa
•
(motor 2 opening delay time)= In the opening phase the second motor
delays its start. The default time set by Stagnoli is 1 and can be regulated from
0 to 10 seconds.
sfac
•
(motor 1 closing delay time)= In the closing phase the fi rst motor delays
its start. The default time set by Stagnoli is 3 and can be regulated from 0 to 10
seconds.
WARNING: before setting the slowing phase, check that the gate has been ba-
lanced correctly. In this phase, the motors have less power and the way this
parameter is set can infl uence the level of safety of the system itself. Once these
parameters have been regulated, check the force of impact of the gate leaves.
rlap
•
(slowed stroke in opening)= the control board slows down the stroke of the
motors in the end part of its opening phase. The default stroke set by Stagnoli is
20 cm and it can be regulated from 0 to 70cm (for 1,8m gate wing).
rlch
•
(slowed stroke in closing)= the control board slows down the stroke of the
motors in the end part of its closing phase. The default stroke set by Stagnoli is 20
cm and it can be regulated from 0 to 70cm (for 1,8m gate wing).
WARNING: before setting the slowing phase, check that the gate has been instal-
24
add transmitter
ok
if the operation has been carried out correctly,
full
if the receiver memory is full.
move over the wording display
1ch
2ch
or
premi
err
if there
ttca
time is
en=0
, the command