Why shall I have to choose a rolling code transmitter instead of a fi x one?
The rolling code transmitters are safer as they can't be cloned and have 200 million
combinations. They change for every transmission. On the contrary, the fi x code tran-
smitters have 1024 code combinations. They don't change for every transmission.
Can the control board run the operation of the motor with emergency batteries?
Yes. To use emergency batteries use the kit supplied by Stagnoli.
The station does not recognise the transmitter. Why?
Check that you are using the same type of station and transmitter. It is possible to
check the type of transmitter used by the station from the main screen and change if
cf
necessary by setting the parameter
.
Once the motor gets to the stop, it turns back instead of arresting. Why?
One reason that can make the control board loose its parameters is that the motor
has been working while unlocked. To be sure that the control board has found back
its parameters, shut off the supply, make sure that the motor is locked and then put the
supply back to the control board. At the fi rst START input, the control board will fi nd
again its parameters.