one second, the inverter is still in working status.
When the inverter faults, screen flashes red and displays error code, the related indicators
will be shaded, buzzer beeps every 0.5 second.The buzzer and backlight will be turned off
after 60 seconds, the screen flashes error code only. If the battery voltage is lower than
10.5V, the display will be turned off.
1.2 Single Charging Mode
system.
When connecting to the solar panel or any sources of AC power, the buzzer beeps and all
shaded indicators will be illuminated for approximately 3 seconds, the backlight will be
illuminated for 10 seconds and then turned off.
Single Charging Mode
Figure 3.1.2
Under single charging mode, following indicators will be displayed:
a.
Battery capacity
b.
c.
Battery indicator
d.
Solar charging indicator
3-2
-
any input power is available and no loads are connected to the
Solar Charging (Backlight)
Note: Real color of display is blue.)
(
AC Charging (Backlight)
Note: Real color of display is blue.)
(
d
b
Solar and AC Charging (Backlight)
Note: Real color of display is blue.)
(
Input power
e
a
c