7.2.3 - Level two functions (adjustable parameters)
Imput Led
Parameter
L1
Motor force
Step-by-step
L2
Function
L3
Pause Time
Note – "
" represents the factory setting.
All the parameters can be adjusted as required without any contraindication; only the adjustment of the "motor force" could require special care:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the safety system
or damage the leaf.
• If the "motor force" control is used to assist the impact force reduction system, measure the force again after each adjustment in compliance with EN
standard 12445.
• Wear and weather conditions may affect the movement of the gate, therefore periodic re-adjustments may be necessary.
7.2.4 - Level two functions (adjustable parameters)
The adjustable parameters are factory set as shown in table 15, with: "
cedure carefully, as there is a maximum time of 10 seconds between pressing one button and another. If a longer period of time lapses, the procedure will finish
automatically and memorize the modifications made up to that stage.
01. Press the button [Set] and hold it down (approx. 3 s)
02. Release the [Set] button when L1 LED starts flashing
03. Press button [st] to move the flashing LED onto the input LED representing the parameter which is to be changed
04. Press the button [Set] and hold it down during step 5 and 6
05. Wait approx. 3 seconds, after which the LED representing the current level of the parameter which is to be modified will light up
06. Press button [st] to move the LED representing the parameter value
07. Release the button [Set]
08. Wait 10 seconds before leaving the programme to allow the maximum time to lapse
Note – Points 3 to 7 can be repeated during the same programming phase in order to set other parameters.
7.2.5 - Level one programming example (ON-OFF functions)
The sequence to follow in order to change the factory settings of the functions for activating "High Speed" (L2) and "Automatic Closing" (L3) have been included
as examples.
01. Press the button [Set] and hold it down (approx. 3 s)
02. Release the [Set] button when L1 LED starts flashing
03. Press the [st] button once to move the flashing LED to LED L2
04. Press the [Set] button once to change the state of the function associated with L2 (Motor Speed)
LED L2 will now flash with long flashes
05. Press the [st] button once to move the flashing LED to LED L3
06. Press the [Set] button once to change the state of the function associated with L3 (Automatic Closing)
LED L3 will now flash with long flashes
07. Wait 10 seconds before leaving the programme to allow the maximum time to lapse
Once these operations have been completed, LEDs L2 and L3 must remain on to indicate that the "High Motor Speed" and "Automatic Closing" functions
.
are active
8 – English
TABLE 15 - Elenco funzioni programmabili: secondo livello
Led (level)
Value
L1
Low
L2
Medium
L3
High
L1
Open - stop - close - open
L2
Open - stop - close - stop
L3
Condominium operation
L1
15 seconds
L2
30 seconds
L3
60 seconds
". However, they can be changed at any time as shown in Table 16. Follow the pro-
TABLE 16 - Changing the adjustable parameters
TABLE 17 - Level one programming example
Description
Adjust the sensibility of the motor force control to suit
the type of gate. The "High" adjustment is more suitable
for heavier and larger gates
Manages the sequence of controls associated to the
Step-by-Step input or to the 1st radio command (see
tables 4 and 5)
Adjusts the pause time, namely the time which lapses
before automatic closure. This will only have an effect if
automatic closing is active
SET
3 s
SET
L1
SET
SET
SET
10 s
SET
3 s
SET
L1
L2
SET
L3
L3
SET
L2
10 s