Ingeteam
Category III - 1000-Volt measuring instruments must be used for checking for the absence of voltage.
Ingeteam accepts no liability for any damages caused by improper use of the equipment. You must
propose in advance to Ingeteam any work carried out on any equipment which implies a modification
of the original electrical arrangements. These must be studied and approved by Ingeteam.
Potential hazards for people
The equipment may remain charged after disconnecting the renewable power supply.
Carefully follow the mandatory steps in the manual for removing the voltage.
Always follow the indications in the manual on moving and placing the unit.
The weight of this unit can cause injury if not handled correctly.
DANGER: High temperature.
The flow of outlet air can reach high temperatures which can cause injury to anybody exposed to it.
Potential hazards for the equipment
The unit requires impurity-free air flow while it is operating.
Keeping the inlets free of obstacles is essential for this air flow to refrigerate the unit.
After all duly authorized handling, check that the inverter is ready to start operation. Only after this
can you connect it, following the instructions in the manual.
Do not touch boards or electronic components. The more sensitive components can be damaged or
destroyed by static electricity.
Do not disconnect or connect any terminal while the unit is operating. Disconnect and check for
absence of voltage first.
Personal Protective Equipment (PPE)
When working on the unit, use the following safety equipment recommended by Ingeteam as a minimum.
Name
Safety footwear
Helmet with face shield
Working clothes
Dielectric gloves
Tools and / or equipment used in live work must have at least Category III-1000 Volts insulation.
Should the country's regulations demand another kind of personal protection, you should appropriately supplement
the equipment recommended by Ingeteam.
50
In compliance with standard UNE-EN-ISO 20345:2012
In compliance with standard UNE-EN 397:1995, provided there are elements
with directly accessible voltage.
Close-fitting, non-flammable, 100% cotton
In compliance with standard EN 60903:2005
ABE2011IQM01_B - Installation and Operation Manual
Important Safety Instructions
Explanation