Technical Data; General Data And Operating Conditions - Lenze E94ASHE Serie Instrucciones Para El Montaje

Ocultar thumbs Ver también para E94ASHE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3

Technical data

3.1

General data and operating conditions

Supply system data
Supply forms
Noise emission
Noise immunity
Conformity and approval
Conformity
CE
Approval
UL
Protection of persons and devices
Enclosure
Insulation resistance
Insulation of control
circuits
Short-circuit strength
Motor protective
measures against
Discharge current
Cyclic mains switching
Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
EDK94SH366 DE/EN/FR/ES/IT 3.1
General data and operating conditions
With earthed neutral Unrestricted use
IT systems
Observe instructions about special measures!
EN 61800-3
Cable-guided, up to 150 m motor cable length: category C2
Radiation: category C3
EN 61800-3
Category C3
73/23/EEC
Low-Voltage Directive
UL 508C
Power Conversion Equipment, File No. 132659
EN 60529
IP 20
NEMA 250
Protection against contact to
type 1
EN 61800-5-1
Overvoltage category III
Reduction from 2000 m amsl onwards: Overvoltage category
II
EN 61800-5-1
Safe mains isolation by double/reinforced insulation.
EN 61800-5-1
Motor connection: with restrictions, fault acknowledgement
required
Control connections: without restrictions
Short circuit
Earth fault
Overvoltage
Motor stalling
Motor overtemperature
(PTC or thermal contact, I
EN 61800-5-1
> 3.5 mA
Cyclic mains switching of 5-times in 5 minutes permissible
without restrictions.
IEC/EN 60721-3-1
1K3 (-25 ... +60 °C)
IEC/EN 60721-3-2
2K3 (-25 ... +70 °C)
IEC/EN 60721-3-3
3K3 (-10 ... +55 °C)
Power derating at +45 ... +55 °C: 1 %/°C
0 ... 4000 m amsl
Power derating at 1000 ... 4000 m amsl: 5 %/1000 m
EN 61800-5-1
Degree of pollution 2
IEC/EN 60068-2-6
Sinusoidal: 0.7 g RMS, 20 ... 250 Hz
IEC/EN 60068-2-64
Noise: 0.7 g RMS, 20 ... 250 Hz
Technical data
Not in the wiring range of
the terminals on the
motor side
2
t monitoring)
Observe regulations and
safety instructions!
3
73

Publicidad

Tabla de contenido
loading

Tabla de contenido