Master Serial Port Format
Selects the format used by the device (when operating in master mode) during modbus RTU serial
communication
8 bit, no parity, 1 stop bit (
8-N-1
8 bit, even parity, 1 stop bit
8-E-1
8 bit, odd parity, 1 stop bit
8-o-1
8 bit, no parity, 2 stop bit
8-N-2
8 bit, even parity, 2 stop bit
8-E-2
8 bit, odd parity, 2 stop bit
8-o-2
164
Variable 1
Selects the variable 1 used by the device in master mode.
Reserved
----
Write Process (
W. Pro.
Read/write command setpoint
r .W.c .SE .
Write command output percentage
w.c .ou.p .
Read/Write Alarm 1 setpoint
r .W.A1 .s.
Write constant
W.cons.
Read Process (remote process from modbus master)
r . Pro.
165
Variable 1 Address
Sets the address used by the master to write/read
0..65535.
: 1000.
Default
166
Lower Limit Variable 1
Lower range limit used for rescaling variable 1
[digit
-9999..+30000
167
Upper Limit Variable 1
Upper range limit used for rescaling variable 1
[digit
-9999..+30000
168
Constant 1
Sets the constant value that will be transmitted while operating in master mode, if selected on
0..65535.
: 0.
Default
169
Variable 2
Selects the variable 2 used by the device in master mode.
Disabled (
di sab.
Write Process
W. Pro.
Read/write command setpoint
r .W.c .SE .
Write command output percentage
w.c .ou.p .
Read/Write Alarm 1 setpoint
r .W.A1 .s.
Write constant
W.cons.
170
Variable 2 Address
Sets the address used by the master to write/read
0..65535.
: 1001.
Default
171
Lower Limit Variable 2
Lower range limit used for rescaling variable 2
[digit
-9999..+30000
172
Upper Limit Variable 2
Upper range limit used for rescaling variable 2
[digit
-9999..+30000
173
Constant 2
Sets the constant value that will be transmitted while operating in master mode, if selected on
0..65535.
: 0.
Default
174
Transmission Delay
Defines the minimum delay introduced by the modbus master protocol between the full data
reception by the slave and a new query.
0..200 ms.
Default
Default
)
Default
] (degrees for temperature sensors).
1 p. 37
] (degrees for temperature sensors).
1 p. 37
)
Default
] (degrees for temperature sensors).
1 p. 37
] (degrees for temperature sensors).
1 p. 37
: 2 ms.
)
Default
Default
Default
Default
: 0.
:0
: 0.
:0
35