USER'S MANUAL. PROLITE-40
7

SELECTING FUSION PROGRAM PROGRAMER

7.1

Overview of fusion program

PROLITE-40 Fusion splicer has 200 kinds of fusion program (100 kinds for SM,
100 kinds for MM).
1.- Factory setup program No.1~No.5.
2.- Users setup program No.7~No.100.
3.- Program No.6 is saved program after test the current is suitable.
4.- You should select proper fusion program base actual splice fiber (SM or MM).
7.2

Selecting fusion program

PROLITE-40 provides function to correct arc current automatically, to satisfy
different requirement; you can select different fusion parameters. The operations are as
follows:
1.- Press
to enter the first class menu.
2.- Press
or
3.- Press
or
4.- Press
or
5.- Press
or
6.- Press
to enter program parameter menu.
7.- Press
or
8.- Press
or
9.- Press
to save program parameter after confirming.
02-2011
to make cursor point to "Fusion fiber".
to select the value of "Fusion fiber".
to make cursor point to "Fusion program".
to select needed arc program.
to make cursor point to modifiable parameter.
to increase or decrease the quantity of selected parameter.