USER'S MANUAL. PROLITE-40
You can base need to select "if test tension", then operate. After splicing the
screen displays as right picture. Press
automatically. If you don't want to test tension, then press "RESET" to reset system
after taking out spliced fiber or do not select "Test tension".
4.5
Protection of fusion point
Taking out spliced fiber
Raise windshield and fiber-collect in turn, take out spliced fiber, do not touch
electrode.
Moving splice protection sleeve
Move splice protection sleeve that covered around fiber to joint, make sure that length
of two fiber's coat is equal in splice protection sleeve. Consult figure 9 (a).
Heating splice protection sleeve
1.- Open heater and put the splice protection sleeve into it.
2.- Press
. to heat splice protection sleeve when light is on.
3.- After time is up, the light will stop heating automatically.
4.- Place the fiber in the cooling tray to cool.
Figure 9 (a) and 9 (b) are the good examples; 9 (c) is the bad example. If the
phenomenon as 9 (c) appears you should remake the joint and check whether there is
dust in the splice protection sleeve and on bare fiber, then heat it.
02-2011
to make PROLITE-40 to test tension