Pre-Fusion Current And Pre-Fusion Time; Fusion Current And Fusion Time; Push Speed And Fusion Push; Working Mode - Promax PROLITE-40 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cursor point to the optional or modifiable content, press
cursor; The next line's number is value of the item, press
modification quantity in the bottom of menu stands for the change quantity of
increase/decrease key, you can press "AUTO" to select among "1,10,100"; Press
to confirm or enter next menu; Press
Remark:
You must press
of parameters are as follows:

5.4.2.1 Pre-fusion current and Pre-fusion time.

After setting gap and adjusting, PROLITE-40 agains to work. In the process, the
fusion splicer will pre-manage the fiber. The range of pre-fusion current is 0.1~24mA,
step-size is 0.1mA; the range of pre-fusion time is 10~1000 mS, step-size is 10 mS.

5.4.2.2 Fusion current and fusion time

It is the current value and arc time. The range of fusion current is 0.1~24mA, step-
size is 0.1mA; the range of pre-fusion time is 0.1~10S, step-size is 0.1S. (The value of
current can be tested automatically base on the arc testing).

5.4.2.3 Push speed and fusion push

PROLITE-40 will wrap part fiber in the process of fusion, these two parameters
decide speed of fiber and quantity of wrap. The range of push speed is 1~30 mS, step-
size is 1 mS; the range of fusion push is 1~100 µm, step-size is 1 µm.

5.4.2.4 Working mode

The manual/Auto mode is optional. "1" is Auto mode and "2" is manual mode.
Page 22
to exit current menu.
to confirm after modifying the value. The explanations
USER'S MANUAL. PROLITE-40
or
to move the
or
to modify; The
02-2011

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido