SPECIFICATIONS
Common Specifications
NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Source
Power Factor
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Output to Motor
Frequency Range
Current (max)
Wire Gage Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R
and Weight
FE 115 VAC Motors
Recommended
FE 230 VAC Motors
For Use With
Other FE Pump and
Motor assemblies
* Operating temperature is specified at full output power when installed as recommended. Refer to
"Over Temperature Foldback" on page 30
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
SubDrive Utility
5870202003 with Pressure Sensor
5870202003XC with Pressure Transducer
115/230 ± 10% VAC
Single-Phase
60 Hz
20 A
~ 0.52
3 Watts
2.5 kW
Refer to
"Fuse/Circuit Breaker and Wire Sizing" on page
230 VAC Maximum
Single-Phase (2-Wire)
35 – 63 Hz Submersible
40 – 63 Hz Surface
13.1 A (based on motor SFA)
Refer to
"Maximum Motor Cable Length" on page
50 psi (3.4 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
Transducer: 5-95% of transducer range
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 16-3/4" x 5-1/4" : 20 lbs
(25 x 42.5 x 13 cm) : (9 kg)
244502 - series (1/3 hp, 0.25 kW) single-phase, 2-Wire
244504 - series (1/2 hp, 0.37 kW) single-phase, 2-Wire
244505 - series (1/2 hp, 0.37 kW) single-phase, 2-Wire
244507 - series (3/4 hp, 0.55 kW) single-phase, 2-Wire
244508 - series (1.0 hp, 0.75 kW) single-phase, 2-Wire
244502 - series (1.5 hp, 1.1 kW) single-phase, 2-Wire
MH, BT4, VR, DDS, VersaJet, C1
.
Common Specifications
19.
20.
SPECIFICATIONS
39