For new parameter-values to apply after the AC supply to the drive is interrupted, new
NOTE
values must be saved. Refer to section 5.7 Saving parameters on page 20.
5.3
Menu 0
Menu 0 is used to bring together various commonly used parameters for basic easy set
up of the drive.
Appropriate parameters are cloned from the advanced menus into menu 0 and thus
exist in both locations.
For further information, refer to Chapter 6 Basic parameters (Menu 0) on page 23.
Figure 5-5 Menu 0 Cloning
Menu 0
0.04
0.05
0.06
5.4
Menu structure
The drive parameter structure consists of menus and parameters.
The drive initially powers up so that only menu 0 can be viewed. The up and down arrow
buttons are used to navigate between parameters and once level 2 access (L2) has
been enabled (see Pr 0.49) the left and right buttons are used to navigate between
menus. For further information, refer to section 5.11 Parameter access level and
security on page 20.
Figure 5-6 Menu structure
Menu 0
Pr 0.00
Pr 0.01
Pr 0.02
Pr 0.48
Pr 0.49
Pr 0.50
The menus and parameters roll over in both directions.
i.e. if the last parameter is displayed, a further press will cause the display to rollover
and show the first parameter.
When changing between menus the drive remembers which parameter was last viewed
in a particular menu and thus displays that parameter.
Unidrive SP Short Form Guide
Issue Number: 1
Electrical
Getting
Installation
Started
Menu 2
2.21
5
0
150
Menu 4
150
4.07
Menu 1
Menu 2
Pr 1.00
Pr 2.00
Pr 1.01
Pr 2.01
Pr 1.02
Pr 2.02
Pr 1.49
Pr 2.36
Pr 1.50
Pr 2.37
Pr 1.51
Pr 2.38
Moves between Menus
www.controltechniques.com
Running
Advanced
Menu 0
the motor
parameters
5
Menu 1
1.14
0
Menu 21 Menu 22
Pr 21.00
Pr 22.00
Pr 21.01
Pr 22.01
Pr 21.02
Pr 22.02
Pr 21.29
Pr 22.27
Pr 21.30
Pr 22.28
Pr 21.31
Pr 22.29
UL Listing
Diagnostics Appendix
Information
Moves
between
parameters
17