Features Menu (Continued)
Features Settings
Name
F1-9, M.O. Flo
Set Flow
F3-9, M.O. Flo, Wave, Pulse
Activation
F1-2:
Time Duration
F3:
Set Start time
F3:
Stop time
F4:
Start time
F4:
Stop time
F5:
Start time
F5:
Stop time
F6:
Start time
F6:
Stop time
F7:
Start time
F7:
Stop time
F8:
Start time
F8:
Stop time
F9:
Start time
F9:
Stop time
M.O.Flo
Set Run time
M.O.Flo
Set Interval time
Wave, Pulse
Feature Linked
Wave, Pulse
Set Max Speed
Wave, Pulse
Set Min Speed
Wave, Pulse
Period
Value
4-29m
3
/h
(Default 12m
3
/h)
Enabled / Disabled
(Default Disabled)
1 minute - 10 Hours, or 00:01 - 10:00
(Default 00:01)
00:00 - 23:59
Default 06:00 am)
00:00 - 23:59
(Default 06:10)
00:00 - 23:59
(Default 06:20)
00:00 - 23:59
(Default 06:30 am)
00:00 - 23:59
(Default 06:40)
00:00 - 23:59
(Default 06:50 am)
00:00 - 23:59
(Default 07:00)
00:00 - 23:59
(Default 07:10 am)
00:00 - 23:59
(Default 07:20)
00:00 - 23:59
(Default 07:30)
00:00 AM - 23:59
(Default 07:40)
00:00 AM - 23:59
(Default 07:50)
00:00 AM - 23:59
(Default 08:00)
00:00 AM - 23:59
(Default 08:10)
1 - 59 minutes, or 00:01 - 00:59
(Default 00:01)
2 - 255 minutes, or 00:02 - 04:15
(Default 60 minutes, or 01:00)
1-9
(Wave Default 1, Pulse Default 2)
450 - 3450 RPM
(Default 3450 RPM)
400 - 3400 RPM
(Default 400 RPM)
Wave 10 - 300 seconds or 0010 -
0300
(Default 0010)
Pulse 2 - 300 seconds or 0002 -
0300
(Default 0002)
Description
Programs the rate of Å ow for feature 1 - 10
When this setting is set to Enabled, the feature activates at the time
speciÄ ed in the "Set Start Time" setting. If this setting is set to Disabled,
the feature does not activate.
Sets the length of time for which Feature 1 or 2 will operate.
Time duration must be selected for Feature 1 and 2.
Sets start time for feature 3
Sets stop time for feature 3
Sets start time for feature 4
Sets stop time for feature 4
Sets start time for feature 5
Sets stop time for feature 5
Sets start time for feature 6
Sets stop time for feature 6
Sets start time for feature 7
Sets stop time for feature 7
Sets start time for feature 8
Sets stop time for feature 8
Sets start time for feature 9
Sets stop time for feature 9
Sets the duration of time over which the M.O.Flo feature will operate the
pump at the intervals speciÄ ed in the "Set Interval Time" setting, and at
the rate speciÄ ed in the "Set Flow" setting
Sets the time between activations of the pump at the rate speciÄ ed in
the "Set Flow" setting
Refers to the feature to which the Wave or Pulse feature is linked
Sets the highest pump speed, in Rotations Per Minute (RPM), at which
the Wave or Pulse feature will operate
Sets the lowest pump speed, in Rotations Per Minute (RPM), at which
the Wave or Pulse feature will operate
For the Wave feature, this setting sets the length of time it takes for the
pump to transition between the values set in the "Max Speed" and "MIn
Speed" settings. For the Pulse feature, this setting determines the length
of time the pump will maintain a randomly generated speed between the
values set in the "Max Speed" and "Min Speed" settings.
IntelliFlo VF Installation and User's Guide
37