Drive Assembly Removal And Installation - Pentair Water Pool and Spa IntelliFlo VF Manual Del Usuario

Ocultar thumbs Ver también para IntelliFlo VF:
Tabla de contenido

Publicidad

56

Drive Assembly Removal and Installation

To remove the IntelliFlo drive and control panel from the motor assembly:
1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Disconnect the communication cable from the pump.
3. Open the control panel cover.
4. Remove the three Phillips head screws securing the drive to the motor assembly as shown.
CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE TAMPER
PROOF SCREWS (QTY 4) FROM THE MOTOR ASSEMBLY
5. Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping
moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a
damaged or missing gasket.
To install the IntelliFlo drive assembly onto the motor assembly:
1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Ensure that the gasket between the drive and motor is in place. It is critical in keeping moisture out
of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or missing
gasket.
3. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
4. Secure and tighten the drive assembly with the three Phillips head screws.
Phillips head screw
Do not remove these
screws
Orange motor post
caps (QTY. 3)
IntelliFlo VF Installation and User's Guide
Phillips head screws
Gasket
Adapter connector

Publicidad

Tabla de contenido
loading

Productos relacionados para Pentair Water Pool and Spa IntelliFlo VF

Tabla de contenido