Set "STBY" knob to other position except for "∞" and "OFF" under auto
mode, detector will enter into standby mode when the delay off time is
expired, and load will change to turn on according to the setting of
"STBY%" for the time setting by STBY knob or IR remote control. During
which, if the movement is detected, load will turn on with the setting
illumination (100% or the dimmed illumination) and then turn to the
setting illumination of "STBY%" if no movement detected and the delay
off time expired. Afterwards, if it is still have no movement detected and
the STBY setting time is expired, load will turn off.
•
Set "STBY" knob to "OFF", load will turn off when the delay off time
is expired.
Auto dimming (constant light level control)
According to the changeable ambient light level, the load can dim to be
bright or dark automatically to match the Lux setting value (Lux setting
value by IR or knob is measured the mixed light level of artificial light and
the ambient light).ambiente).
Manually ON / OFF switching function
Terminal of R/S and push button (N.O. type) can be series connected to
manually switch on / off load.
(case 1: on → off; case 2: off → on). While pressing push button(≤1sec):
Case 1: Manual off switching (Lux settings is invalid):
Under the light on status, the light can be manually switched off by short
pressing (≤1sec) the push button. During this operation mode, once the
detector is triggered by movement, the light keeps be off within the set
switch off delay time. Until there is no movement detected and the pre-set
switch off delay time has reached, the detector resumes to work according
to the previous operation mode set by knobs or IR. To press the push
button (≤1sec) during the light manual off period will activate the manual
light on function (working as Case 2).
Case 2: Manual on switching (Lux settings is invalid):
Under the light off status, the light can be manually switched on by short
pressing (≤1sec) the push button. During this operation mode, once the
detector is triggered by movement, the light keeps be on within the
pre-set switch off delay time. Until there is no movement detected and the
pre-set switch off delay time has elapsed, the detector resumes to work
according to the previous operation mode set by knobs or IR. To press the
push button (≤1sec) during the light manual on period will activate the
manual light off function (working as Case 1).
www.grupotemper.com
Presence detector for DALi lighting control
KDP-DALI 01
Instructions manual |