Technical Data; Disposal - Grundfos Intertek MAGNA1 Installation And Operating Instructions

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

13. Technical data

Supply voltage
See pump nameplate for rated supply voltage:
1 x 115 V ± 10 %, 50/60 Hz, PE.
1 x 208-230 V ± 10 %, 50/60 Hz, PE.
Motor protection
The pump requires no external motor protection.
Enclosure class
Enclosure Type 2.
Insulation class
F.
Relative air humidity
Maximum 95 %.
Ambient temperature
+32 to +104 °F (0 to +40 °C).
During transport: -40 to 158 °F (-40 to +70 °C).
Temperature class
TF110 (EN 60335-2-51).
Liquid temperature
Continuously: +14 to +230 °F (-10 to +110 °C).
System pressure
The maximum permissible system pressure is stated on the pump
nameplate:
175 psi (12 bar).
Minimum inlet pressure
The following relative minimum inlet pressure must be available
at the pump inlet during operation to avoid cavitation noise and
damage to the pump bearings.
Liquid temperature
Single-head
+167 °F
pumps
(+75 °C)
DN
[psi] / [bar] / [MPa]
32-60/100
1.45 / 0.10 / 0.01
40-80
1.45 / 0.10 / 0.01
40-120/180
1.45 / 0.10 / 0.01
50-80
1.45 / 0.10 / 0.01
50-150
10.1 / 0.70 / 0.07
65-120
10.1 / 0.70 / 0.07
65-150
10.1 / 0.70 / 0.07
80-100
7.25 / 0.50 / 0.05
100-120
10.1 / 0.70 / 0.07
The actual inlet pressure plus pump pressure
Note
Note
against a closed valve must be lower than the
maximum permissible system pressure.
+203 °F
+230 °F
(+95 °C)
(+110 °C)
Inlet pressure
5.1 / 0.35/ 0.035
14.5 / 1.0 / 0.10
7.25 / 0.50 / 0.05
14.5 / 1.0 / 0.10
7.25 / 0.50 / 0.05
14.5 / 1.0 / 0.10
5.8 / 0.40 / 0.04
14.5 / 1.0 / 0.10
17.4 / 1.20 / 0.12
24.65 / 1.7 / 0.17
17.4 / 1.20 / 0.12
24.65 / 1.7 / 0.17
17.4 / 1.20 / 0.12
24.65 / 1.7 / 0.17
14.5 / 1.00 / 0.10
21.75 / 1.5 / 0.15
17.4 / 1.20 / 0.12
24.65 / 1.7 / 0.17
The relative minimum inlet pressures apply to pumps installed up
to 984 ft (300 m), above sea level. For altitudes above 984 ft
(300 m), the required relative inlet pressure must be increased by
0.145 psi / 0.01 bar / 0.001 MPa per 328 ft (100 m) altitude.
The MAGNA1 pump is only approved for an altitude of 6561 ft
(2000 m) above sea level.
EMC (electromagnetic compatibility)
EN 55014-1:2006, EN 55014-2:1998, EN 61800-3-3:2008 and
EN 61000-3-2:2006.
Sound pressure level
The sound pressure level of the pump is lower than 43 dB(A).
Leakage current
The pump mains filter will cause a discharge current to earth
during operation. I
< 3.5 mA.
leakage
Power factor
The MAGNA1 has built-in PFC (Power Factor Correction) which
gives a cos φ from 0.98 to 0.99, i.e. very close to 1.

14. Disposal

This product has been designed with focus on the disposal and
recycling of materials. The following average disposal values
apply to all variants of Grundfos MAGNA1 pumps:
85 % recycling
10 % incineration
5 % depositing.
This product or parts of it must be disposed of in an
environmentally sound way according to local regulations.
Subject to alterations.
21

Publicidad

Tabla de contenido
loading