Ce Labelling; Connections; Assemblies - Vaillant atmoMAG mini 11-0/0 XI Instrucciones De Uso

Ocultar thumbs Ver también para atmoMAG mini 11-0/0 XI:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

a
Danger!
Risk of explosion due to wrong type of gas!
The wrong type of gas may lead to hazardous
situations.
>
Before start-up of the unit compare the
details concerning the set type of gas on
the identification plate with the type of gas
supply at the installation site.
>
Always note the appliance type and the gas type used
in Table 10.2, with reference to the set gas type in
section 10, Technical data.
>
Put the housing back on the appliance.
3.2

CE labelling

CE labelling shows that the appliances comply with the
basic requirements of the following directives:
Gas appliances directive (2009/142/EG)
Electromagnetic compatibility directive with thresh-
old class B (2004/108/EG)
Low voltage directive (2006/95/EG)
3.3

Connections

a
Danger!
Risk of scalding and damage from escaping
hot or cold water!
Incorrect installation may cause leaks. Plastic
pipes for the hot and/or cold water connec-
tion must be resistant to temperatures up to
95 °C and resistant to pressures up to 1 MPa
(10 bar).
>
In order to prevent leaks, ensure that no
mechanical stresses arise in the pipework.
>
Ensure that there are no stresses in the
hot and cold water connections when
installing them.
Appliance connections:
– Water 3/4"
– Gas 1/2"
>
Determine where the unit is to be installed.
>
Route the gas and water pipes to the connecting
points on the unit.
Installation manual atmoMAG mini 11-0/0 XI 838291_05
Description of the appliance 3
3.4

Assemblies

11
10
9
8
Fig. 3.1 Assemblies
Key
1
Flue gas sensor
2 Flow cutout
3 Safety thermostat
4 Heating element
5 Ignition electrodes
6 Burner
7 Temperature selector
8 Battery compartment
9 Power switch
10 Gas fitting
11 Monitoring electrode
1
2
3
4
5
6
7
INT
7
EN

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido