5 Installation
5.3
Connecting to the flue system
Fig. 5.1 Flue connection
Key
1
Flue pipe
2 Flow cutout pipe opening
5.3.1
Checking the flue gas sensor
Check that the flue gas sensor is working before you fit
the flue pipe. This is how to do it:
>
Block the flue exit.
9
Abb. Setting the maximum temperature and performance
>
Turn the power switch (1) clockwise to the maximum
temperature.
>
Turn the power switch (9) anticlockwise to maximum
performance.
>
Open the hot water tap.
The flue gas sensor must cut off the gas supply within
two minutes and shut off the appliance.
You can start the appliance again after the flue gas sen-
sor cools down (at least 15 minutes).
12
1
2
Fig. 5.3 Resetting the appliance
To reset the appliance, either:
>
Close the water tap and open it again without press-
ing the main switch, or
>
Leave the water tap open and switch the appliance
off and on again by pressing the main switch (5)
twice.
If the flue gas sensor does not act in this time:
>
Contact customer service.
>
Put the appliance out of operation.
5.3.2 Fitting the flue pipe
>
Fit the flue pipe (1) in the flue pipe connection (2) on
the flow cutout, see fig. 5.1.
1
Installation manual atmoMAG mini 11-0/0 XI 838291_05
5