[3 Standard Twin Burner Models
(models with lift-up cooktops)
1, Lift the cooktop
2, Lift
the
burner
assemblies
straight
up and
set aside
to gain
access
to
sur*
face
burner
spud&
3. With
a
7mm,
5/16"
or a small
adjustable
wrench
(depend-
ing on the
size
needed),
remove each of the four spuds on the su_-
face burner
gas inlet tubes and replace
them with
the correct
gas spuds
mounted
in a holder
at the
right rear of the range, above the regulator., Natural
gas spuds are brass and LP gas spuds are red or
silver.. (Mount the spuds that you removed
from the
inlet tubes back in the holder..) To prevent leakage,
make
sure spuds
are securely
screwed
into gas
inlet tubes.
4. Replace the burner assemblies..
5. Keep all spuds with your range so you have them if
you move or get a different
gas hook-up.
Top Burner
Orifice
Drill Size
Color
Natural Gas
#54 (°0550 D!,a;,)
.....Brass
LP (Propane)
#66 (.0330 Diao)
Red or Silver
Step 3
Convert the Oven Burner Orifices
Oven Burner
1. Remove
oven door, storage drawer
or broiler draw-
er and oven bottom. The lower burner orifice spud
is tocated behind the storage
drawer, broiler drawer
or kick panel.
(On some
models,
a metal
shield
must be removed
to access the orifice.)
2. To convert
to LP gas, use a
1/2" wrench
to turn the lower
burner
orifice
spud
clockwise.
Tighten
the spud only until it is
snug.
To prevent
damage,
do
not overtighten
the spud.
To convert
to
natural
gas,
loosen the spud about 2 turns.
Broil Burner
(on some models)
To convert
to LP gas, use a 1/2" wrench
to turn the
upper
burner
orifice
spud
clockwise.
Tighten
spud
only until it is snug with the base_ To prevent damage,
do not overtighten
spud°
To convert
to natural
gas, loosen
the spud
about
2 turns.
Step
4
Convert Air Adjustment
Shutter(s)
For LP gas, loosen the Phillips
head screw and rotate the shut-
ter to the full open position.
With
baffle
in place,
flames
should
have approximately
1" (2.5 cm)
blue
cones
and
should
not
extend beyond
the edges of the
burner baffle° After 30 seconds
of burner
operation,
check
for
sc.4
Air
Shutter
flames
lifting
off burner
ports.
If lifting
is observed,
gradually
reduce
air shutter
opening
until flames
are
stabilize&
For
natural
gas,
the shutter
should
be open
t/2"
(I.3 cm) or about 3/4 of the way open_
(continued next page)