40
1.3

Technical Specifications

Translation of the legally binding German version
CE sign:
Country of
origin:
Measurement
parameters:
Capture of
measurement value: Flow time: Optoelectronic or thermo-resistive capture of the meniscus passage
Optional parameters: to be set using the WinVisco 370 software
Method:
:
Viscometers
ViscoPump:
:
Time for temperature
Number of
:
measurements
Measurement
ranges:
Viscosity:
Time:
:
Pumping pressure
Measurement
precision:
Time
measurement:
Data transfer
parameters:
Data
interface:
Data
format:
ConnectionsBack panel of the
Data in- and
output:
Spill-over guard
VZ 8551
for waste
bottle:
Bath
backlighting:
Pump connector:
Mains
connector:
To be connected to the front panel of ViscoPump II
EMC compatibility according to the Council Directive
applied harmonized standards:
Low-voltage directive according to the Council Directive
applied harmonized standards:
Germany, Made in Germany
Flow time in seconds [s]
through the measurement planes of the viscometers
Absolute or relative viscosity
Ubbelohde viscometers (DIN, ASTM, micro); micro Ostwald; Cannon-Fenske
TC Ubbelohde viscometers and dilute-solution viscometers
Pump parameters (ramp, pressure, suck over N1)
adaption: 0...20 min, to be selected in increments of 1 min
1...
10 for each sample
"pressing" mode 0.35 ... 1.800 mm
"sucking" mode 0.35 ... 5.800 mm
Resolution
0.01 s
Fully automatically controlled "sucking" action to approx. -160 mbar
Fully automatically controlled "pressing" action to approx. +160 mbar
Precision (reproducibility and comparability) in accordance with DIN 51562, Part 1
± 0.01 s ± 1 digit, but not more accurate than 0.01 %
measurement incertainty in the determination of absolute, kinematic viscosity furthermore
depends on the incertainty of the numerical value of the viscometer constants and the
/measurement conditions, especially as concerns themeasurement temperature.
bi-direktional serielle interface according to EIA RS-232-C
word length 7 bits, 2 stop bits, 4800 baud, no parity
device:
2 serial RS-232-C interfaces: 9-channel sub-miniature D sockets
st
1
serial interface: Connection of a personal computer (PC)
nd
2
serial interface: Connection of a
DIN round plug connector 4 channels with screw-type cap according to DIN 45321
Circula connectors with bayonet lock DIN 4 pin, 24 V, 350 mA
Cold-device socket in accordance with EN 60320 for connecting a 230 V or
115 V vacuum pump. The nominal voltage of the vacuum pump has to match the
nominal operating voltage of the
Max. power consumption required for the operation of the pump 2.5
Max. performance with 115 V: 285 VA
Max. performance with 230V: 575 VA
Device plug with safety interrupter according to VDE 0625, IEC 320/C14,
EN 60320/C14, DIN 49 457 B
2004/108/EG;
EN 61326/1:2006.
EN 61 010, Teil 1.
2
/s (cSt) measuring temperature of approx. 20 ... 25 °C
2
/s (cSt) measuring temperature of approx.
®
TITRONIC
, or a
®
AVS
370.
modules:
(Release 8. July 2016)
2006/95/EG;
routine;
20 ... 25 °C
nd
®
2
AVS
370
A

Publicidad