Lenze L-force 9400 Serie Instrucciones Para El Montaje página 41

Control de freno de motor
Ocultar thumbs Ver también para L-force 9400 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Control connection
Terminal X117
SSP94A6117
Terminal data
Flexible
With wire end
ferrule
Stripping length or contact length: 8 mm
Digital output DO
State
HIGH
LOW
EDK94AZHN25 DE/EN/FR/ES/IT 2.3
Labelling
Description
DI
Digital input
GI
GND digital in
DO
Signalling output
24V
24−V supply by safely separated power supply unit
(SELV/PELV)
GND
GND digital out
Conductor cross−section
2
[mm
]
0.5 ... 2.5
20 ... 12
Description
No fault
Fault
l
Supply voltage of the motor holding brake is missing
l
Motor holding brake is not connected
l
Brake cable is defective
– Open circuit
– Short circuit
l
Supply voltage of the motor brake control is missing
l
Electrical installation
[AWG]
[Nm]
Connection data
Tightening torque
[lb−in]
Spring terminal
4
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

L-force e94azhn0025E94azhn0025

Tabla de contenido