2.4.1) Electrical diagram
1
2
3 4
5
L N
WARNING: Connection of photocells with Phototest (see chapter 2.4.4)
Note: pre-programmed control unit set for automatic measuring of working time (see chapter 2.5.1)
2.4.2) Description of connections
A brief description of the possible control unit output connections follows
Terminals
1÷3
4
56
7÷9
10÷12
13÷14
15÷16
17
18
19
20
21
22
23
24÷25
* With 2 motors, the first to move in the opening cycle is the M2 motor.
The A400 control unit automatically recognises if there is just one motor installed which must be connected to M2.
** The auxiliary input AUX may be programmed in one of these functions (see chapter 4 "Programming"):
Function
PARTIAL OPEN type 1
PARTIAL OPEN type 2
OPEN
CLOSE
PHOTO 2
DISABLED
Unless otherwise programmed, the AUX input performs the PARTIAL OPEN type 1 function
6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23
M1
M2
Functions
Description
Power input
Mains power supply
Earth
Motor earth connection
Flashing lamp
Connection of flashing lamp to mains voltage (max. 40W)
Motor 1 *
M1 motor connection (lower leaf)
Motor 2 *
M2 motor connection (upper leaf)
Phototest
TX photocell power output (24Vac max. 100mA)
24 Vac
Power output for services, RX photocells, etc. (24Vac max. 150mA)
Common 24 Vac
Common for all inputs/outputs
SCA
Gate open indicator (24Vac max. 1.5W)
Stop
Input NC with STOP function (emergency, safety shutdown)
Photo
Input NC for safety devices (photocells, pneumatic edges)
Photo1
Input NC for safety devices (photocells, pneumatic edges)
Step-by-Step
Input for cyclical functioning (OPEN STOP CLOSE STOP)
AUX
** Auxiliary input
Aerial
Input for the radio receiver aerial
Input type
Description
NO
Completely opens the leaf connected to the M2 motor
NO
Opens the 2 leafs halfway
NO
Only carries out the open manoeuvre
NO
Only carries out the close manoeuvre
NC
PHOTO 2 function
--
No function
LED OK
24 25
P1
P2
ALT
PP
GB
5