Campbell Hausfeld GR2100 Manual De Instrucciones Y Lista De Piezas página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions and Replacement Parts Manual
Pre-Operation (Continued)
LUBRICATION
CHECK ENGINE AND PUMP OIL LEVELS
BEFORE OPERATING! Follow lubrication
instructions before operating compressor.
1.
Oil is NOT mixed with the gasoline, however adequate
oil supply is necessary for proper engine lubrication.
Refer to the Engine Manual for SAE, API and fill quantity
specifications.
2.
Remove pump fill plug and fill pump with 14.1 oz. of oil.
Use full synthetic motor oil like Mobil 1
use regular automotive oil such as 10W-30. Additives in
regular oil can cause valve deposits and reduce pump life.
For pumps with an oil sight glass, oil level can be monitored
and maintained as shown in Figure 2.
Figure 2
BATTERY SET-UP AND CONNECTIONS
This unit DOES NOT come with a battery or battery cables. A 12
Volt battery must be connected to the unit. The 12 Volt battery
must be at least a U group size number. Using at least 8 AWG
battery cables, a connection must be made from the starter
solenoid on the Honda engine to an in-line 30 amp fuse, and
then to the positive terminal of the 12 Volt battery. From the
negative battery terminal, a connection must be made to the
ground screw located on the left side of the frame. Please refer to
the wiring schematics in this manual. If you have any questions,
please contact customer service at 1-800-746-5641.
All manufacturer's warranties are void if the
battery connections are not made as specifi ed in
this manual.
8
www.campbellhausfeld.com
GROUNDING
1.
2.
®
10W-30. Do not
3.
The following are ground sources approved by the National
Electric Code. Other ground sources may be acceptable.
Refer to the National Electric Code and local regulations for
further ground source information. If not sure of regulations
Full
or procedures, obtain assistance from a qualified (licensed or
certified) electrical technician.
Add Oil
Any rod or pipe used for grounding must be driven to eight feet
deep or buried in the deepest possible trench.
PLUMBING
The GR2300 and GR3300 models include a 2 gallon accumulator
tank. Prior to operation of this unit, the accumulator tank MUST
be connected to your remote air tank. Connect the remote air
tank to the accumulator tank with a minimum of 1/2 inch NPT
fittings and/or 1/2 inch ID hose rated for AT LEAST 200 psi. This
accumulator tank is not to be removed from the unit for any
reason.
connected as specifi ed in this manual.
Use the ground terminal and wing nut on the frame to
connect the unit to a suitable ground source. Securely fasten
the end terminal an approved ground wire (not provided) to
the ground terminal on the frame. Tighten the washer and
wing nut on top of the ground wire end terminal.
The ground wire should be made of #8 gauge wire. Do
not use wire with a higher gauge number. Higher gauge
numbers indicate thinner wire, which may not provide an
adequate ground path.
The other end of the ground wire must be securely fastened
to an approved ground source.
a. An underground water pipe at least ten feet in length
b. A non-corrosive underground pipe at least eight feet in
length and 3/4 inch diameter
c. A steel or iron underground rod at least eight feet in
length and 5/8 inch diameter
d. A non-ferrous rod at least eight feet in length, 1/2 inch in
diameter, and approved for grounding purposes
Do not operate the unit unless the accumulator
tank is properly installed.
All manufacturer's warranties are void if the
2 gallon accumulator tank is not plumbed, and

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gr2200Gr2300Gr3100Gr3200Gr3300

Tabla de contenido