E) Using two or more power lifts (power lifts signify a set of 4, 6, or 8 columns)
The communication shall be performed on different channels, the first configured power lift shall communicate on channel 2, and
the others on different channels (available from 0 to 9).
When a power lift is switched off and a new configuration is performed on another one, the transmission may take place on the
channel of the switched off power lift.
When it will be re-started, a new communication channel shall be suggested, which will be confirmed on all the columns in the set.
F) Simultaneous configuration of two or more power lifts
It is not possible.
If 2 master columns with open configuration are detected, the procedure is blocked.
All installations must be switched off.
Repeat the operation, close the configuration of the bridge before starting the set of a new machine.
Press the ENTER button twice to return to the submenu:
BATTERY: allows you to check the charge level of the battery
FW RELEASE: allows you to check the FW versions (to possibly
communicate to the service)
RADIO INFO: allows you to check the information regarding the
strength of the radio signal.
Slave Column:
RSSI 69 : indicates the level of the Radio signal (between 0 and
100) The optimum level is >50
CH 2 : radio channel on which the column communicates (chan-
nel 2)
ID 2 : number of the bridge column.
Master Column:
RSSI 64 : indicates the level of the Radio signal (between 0 and
100) The optimum level is >50
CH 2 : radio channel on which the column communicates (chan-
nel 2)
COL 2 : total number of the bridge columns.
58
B A T T E R Y 2 4 . 9 1
F W
U 1
F W
U 1
S L A V E
C H
2
M A S T E R
C H
2
0526-M002-3
V
1 0 0 %
V 0 0 . 2 4 . 0 0
V 0 0 . 2 4 . 0 0
R S S I
6 9
I D
2
R S S I
6 4
C O L
2
7