Key lock function
The purpose of the key lock function is to prevent accidental modifi-
cations to the settings or the improper use of the circulator.
When the key lock function is activated, long-pressing the button (A)
is prevented. This prevents the user from entering the circulator's
operating modes setting section.
Enabling/disabling the key lock function is achieved by pressing the
button (A) (fig. 49) for more than 10 seconds. During this step all of
the LEDs (C) will flash for 1 second.
Changing the operating mode (fig. 50)
In normal operating conditions the circulator works with the factory
settings or the last settings carried out.
To change the configuration:
Ensure that the key lock function is deactivated.
Press the button (A) for more than 2 seconds until the LEDs begin
to flash. Short-press the button (A) within 10 seconds and the user
interface will move on to display the next settings. The various avail-
able settings will appear in a cyclic sequence.
If the button (A) is not pressed, the last setting will be stored (fig. 49).
If the button (A) is pressed you can move back to the "active settings
display" again and check that the LEDs (B) and (C) indicate (for 2
seconds) the last setting carried out.
If the button (A) is not pressed for more than 2 seconds the user
interfaces switches to the "Operating status display".
The available settings are shown in fig. 51 along with the related
representation of LED (B) and (C).
IMPORTANT
If the 3 (5 metres) or 4 (4 metres) curves are set the bypass must
be replaced with the one supplied, following the procedure indicated
below (fig. 52):
Remove boiler electrical power by setting the system's main switch
to off.
Close the system taps and empty the boiler heating circuit.
Extract the bypass body cover fixing spring (D).
Extract the bypass body cover (E).
Replace the bypass valve (F) with the one included.
Refit the bypass body cover and its spring.