GB
18. Cleaning the Wallperfect i-spray
spray attachment
1) Screw of the container and empty it. Pull out the suction tub with container seal.
CAution!
Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal
objects.
The ventilation hose and diaphragm are only solvent-resistant to a limited
extent. Do not immerse in solvent, only wipe.
2) Pull the ventilating hose (Fig. 13, 1) at the top from the gun body. Screw off the valve
cover (2). Remove the diaphragm (3). Clean all the parts carefully.
3) Remove the adjustment ring (fig. 14, 1) carefully from the union nut (2).
4) Unscrew the union nut (fig. 14, 2) and remove the air cap (3) and nozzle (4). Clean the
air cap, nozzle seal (5) and nozzle with a brush and solvent or water.
5) Clean the outside of the spray gun and container with a cloth soaked in solvent or
water.
6) Assemble the parts again (see "Assembly").
Assembly
The unit may only be operated with an integer diaphragm (Fig. 13, 3).
1) Place the diaphragm (Fig. 13, 3) with the pin facing upwards on the bottom section
of the valve. Also see the marking on the gun body.
2) Place on the valve cover (Fig. 13, 2) and screw it closed.
3) Place the ventilating hose (Fig. 13, 1) on the valve cover and on the nipple at the gun
body.
Attention! never operate the device if the nozzle seal is either damaged or
missing. if the nozzle seal is either missing or damaged liquids can enter
the device and increase the risk of an electric shock.
4) Push the nozzle seal (fig. 15, 5) over the needle (6); the groove (slot) should point
towards you.
5) Place the nozzle (fig. 15, 4) on to the gun body with the recess facing downwards.
Attention: position of needle must be congruent with the nozzle aperture. (fig.16)
6) Put the air cap (Fig. 17, 3) onto the nozzle (4) and tighten it using the union nut (2)
7) Position the adjustment ring (fig. 18, 1) on the union nut so that the recesses on the
adjustment ring can snap into both horns on the air cap.
8) Place the container seal from below on the suction tube and slide it over the collar,
while turning the container seal slightly.
9) Insert the suction tube with container seal in the gun body.
50
Flexio 580 I-Spray