Main Filter And Control Filter; Individual Filter Bags - Nederman E-PAK 150 DX Manual De Instrucciones

Ocultar thumbs Ver también para E-PAK 150 DX:
Tabla de contenido

Publicidad

10.4.1

Main filter and control filter

Replace the whole main filter and the control filter after approximately
6,000 hours of operation and at least every 3 years. Also, replace the control
filter if damaged or if there is a considerable pressure drop over the control
filter.
To replace the main filter:
1.
Remove the main filter according to Figure 18.
2.
Put the old filter in a large plastic bag, or wrap it in plastic foil, see
Figure 15.
NOTE!
Avoid dust spreading.
3.
Install the new main filter.
NOTE!
After installing the new main filter, check that the filter bags are
correctly grounded, see Section '8.3.2 Ground check measurement'.
To replace the control filter:
1.
Disconnect the exhaust from the unit, see Figure 24, item 1.
2.
Remove the top cover from the unit, see Figure 24, item 2.
3.
Remove the clamping ring securing the hose and filter lid to the inlet, see
Figure 24, item 3.
4.
Put the hose and filter lid aside and remove the control filter by lifting it
straight up, see Figure 24, item 4.
5.
Put the old filter in a plastic bag, or wrap it in plastic foil, see Figure 15.
NOTE!
Avoid dust spreading.
CAUTION! Risk of equipment damage
It is important that no dust, objects or debris are allowed to fall down into
the inlet of the side channel fan.
6.
Check that the two Ø 6 mm hoses connected to the top and side of the
inlet are free from dust or other deposits The hoses are connected to the
Differential Pressure Switch (DPS), see Figure 25.
7.
Insert the new control filter.
8.
Refit the filter lid and clamping ring.
9.
Refit the top cover and the exhaust duct.
10.4.2

Individual filter bags

Replacing individual filter bags is possible, but we recommend replacing the
whole filter package, including the filter panel and locking rings, as it is quicker
and causes less spreading of dust.
Individual filter bags which have been damaged may be replaced, see
Figure 16. Use a robust screwdriver to detach the plastic locking ring.
The coiled spring may be kept for use with the new conductive filter bag,
but a new locking ring is to be used to secure the new conductive filter, see
Figure 17
NOTE!
Never re-use an old locking ring!
E-PAK 150 DX/300 DX/500 DX
EN
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E-pak 300 dxE-pak 500 dx

Tabla de contenido