6.
Maintenance
6.1
Suggested lube
Component
Lube
Gearbox
ESSO Spartan EP460 ISO 460
Pneumatic system
ESSO FEBIS K 32
(conditioning assem-
bly)
Tab. 1:
Lubricants table.
!
The manufacturer is not liable for any damage
caused by use of lubes different from those shown in
the table.
6.2
Cleaning and servicing
Before any cleaning or maintenance inter-
vention, disconnect the MS 63 by means of
the main switch and disconnect the network
plug.
Before any cleaning or maintenance interven-
tion, disconnect the pneumatic system of the
MS 63.
To guarantee full efficiency of the MS 63 and to ensure
functioning without anomalies it is essential to clean
the machine regularly and carry out periodical mainte-
nance.
Maintenance has to be carried out by the operator
in accordance with the manufacturer's prescriptions
shown here below.
6.2.1
Maintenance intervals
Maintenance
Clean the mechanical moving parts, spray
them with nebulized oil or cherosene and lube
with appropriate grease
Remove the condensate from the filter assem-
bly.
Check oil level in the oil nebulizer.
Check transmission belt tensioning in order to
avoid its sliding.
Check the oil level in the gearbox and keep it
always between minimum and maximum level.
Change oil in the oil nebulizer.
Beissbarth GmbH
6.2.2
1. Turn left the red button placed in the lower part of
the water separator.
2. Remove the accumulated condense by pressing the
Standard
same button.
3. Turn back in previous position the red button placed
DIN 51502-CLP
in the lower part of the water separator.
ISO 34-98-CC
ISO VG 32
6.2.3
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Top up oil (see lube table).
6.2.4
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Discharge oil and dispose it (see chap. 7.3).
4. Top up with new oil (see lube table).
6.2.5
1. Unscrew the cap of the tank on the oil atomizer.
2. Act on the screw indicated by the arrow using a
screwdriver and adjust it, in order to have the emissi-
on of 1 oil drop every 3 opening/closing movements
of the bead breaker.
x
x
x
x
x
x
Maintenance | MS 63 | 35
Condensate removal
Nebulizer oil refill
Change oil in the oil nebulizer
Lubricating oil flux calibration
1 695 106 288
en
|
2013-10-30