4. Operation
4.16. System
10-04-2007
17:15
SYSTEM
Measurement units
SYSTEM
Sample ID
Data output
SYSTEM
Measurement units
Sample ID
Data output
SYSTEM
Measurement units
Sample ID
Data output
SYSTEM
Sample ID
Data output
Type of report
SYSTEM
Data output
Type of report
Users
SYSTEM
Type of report
Users
Header
SYSTEM
Users
Header
Identify sensor
SYSTEM
Header
Identify sensor
Stirrer 2
SYSTEM
Identify sensor
Stirrer 2
Date / Time
SYSTEM
Stirrer 2
Date / Time
Language
SYSTEM
Date / Time
Language
Display contrast
SYSTEM
Language
Display contrast
Readjust temp.
SYSTEM
Display contrast
Readjust temp.
Stirring
SYSTEM
Readjust temp.
Stirring
Temperature units
SYSTEM
SYSTEM
Measurement units:
Channel 1 units
Channel 1: pH + EC
Channel 2: ISE
Parameter 1: pH
Save data
Parameter 2: EC
SYSTEM
Sample ID:
Codification:
Automatic: A consecutive number per each sample.
Automatic
Manual: The user introduces by an external PC keyboard a specific ID per
Manual
each sample before starting the measurement.
SYSTEM
Data output: Select "deactivated" if there is neither a printer nor a
Data output
connected PC. If a "printer" is selected the following options will appear:
Deactivated
For printer
For PC
Printer data output, options (see pages 14 and 15):
SYSTEM
SYSTEM
Type of report
Samples by report:
Reduced
Several
Standard
GLP
One sample
SYSTEM
SYSTEM
Users:
User 1
User 2
Yes
No
User 3
SYSTEM
Header
First/second line
_
SYSTEM
SYSTEM
Identify sensor:
Channel 1, pH
Electrode data
Channel 1, pH + EC
Model:_
Serial no.:_
Channel 2, ISE
Save data
SYSTEM
Stirrer 2
Stirrer 2.
When the second stirrer is connected automatically is assigned to
Yes
No
Channel 2.
SYSTEM
Data / Time
04-06-2007
09:30
Monday
SYSTEM
English
Deutsch
Castellano
Français
Italiano
SYSTEM
SYSTEM
Display contrast
Display contrast
∆∆∆∆∆∆∆∆∆∆∆∆
∆∆∆∆∆∆∆∆∆∆∆∆∆∆∆
SYSTEM
SYSTEM
Readjust temp.:
Channel 1 Correction
Channel 1
25.0°C: 0.0 °C
Channel 2
85.0°C: 0.0 °C
SYSTEM
SYSTEM
Stirring
Stir
Stirrer N. 1 OFF
Stirrer N. 1 ON
25%
25%
ON
OFF
SYSTEM
Temperature units
Celsius
Fahrenheit
Measurement units.
See "Change of measurement units" in page 17.
Only with Standard and GLP report
Users: The name will appear on the printed
report (17 characters), up to 10 users.
Report header. Two lines of 40 characters for the
company name, etc, that will appear in the
printed report.
Sensor identification: Model and serial number
of the sensor used in the 2 channels. If the meas-
urement unit is ISE it is possible to introduce up
to 4 different sensors, associated to the calibra-
tion curves. These data will appear on the printed
report.
Temperature readjustment.
See page 20.