TABLE E - list of LEVEL 2 programmable functions Note – (*) represents the factory setting.
Input
Parameter
leds
L1
Pause Time
L2
Step-by-step function
L3
Motor speed
L4
FLASH output
L5
Motor Force on opening
L6
Motor Force on closing
L7
Maintenance notification
L8
Fault log list
Led (level)
Setting
L1
10 seconds
L2
20 seconds
L3 (*)
40 seconds
L4
60 seconds
L5
80 seconds
L6
120 seconds
L7
160 seconds
L8
200 seconds
L1
Open - Stop - Close - Stop - ...
L2 (*)
Open - Stop - Close - Open - ...
L3
Open - Close - Open - Close - ...
L4
Apartment block
L5
Apartment block 2
(more than 2" generates stop)
L6
Step-by-step 2
(less than 2" generates partial open)
L7
Hold-to-run
L8
Semiautomatic open;
Hold-to-run close
L1
Speed 1 (30% - slow)
L2
Speed 2 (44%)
L3
Speed 3 (58%)
L4
Speed 4 (72%)
L5
Speed 5 (86%)
L6
Speed 6 (100% - fast)
L7
Open "speed 4"; Close "speed 2"
L8 (*)
Open "speed 6"; Close "speed 4"
L1
Door Open Indicator
L2
Active if door closed
L3
Active if door open
L4 (*)
Flashing light
L5
Electric block
L6
Electric lock
L7
Suction cup
L8
Maintenance indicator
L1
Force 1 (low)
L2
Force 2
L3
Force 3
L4
Force 4
L5
Force 5
L6 (*)
Force 6
L7
Force 7
L8
Force 8 (high)
L1
Force 1 (low)
L2
Force 2
L3
Force 3
L4 (*)
Force 4
L5
Force 5
L6
Force 6
L7
Force 7
L8
Force 8 (high)
L1
Automatic (based on gravity of manoeuvre)
L2
1,000
L3
2,000
L4 (*)
4,000
L5
6,000
L6
8,000
L7
10,000
L8
12,000
L1 (*)
Result of 1st manoeuvre (most recent)
L2
Result of 2nd manoeuvre
L3
Result of 3rd manoeuvre
L4
Result of 4th manoeuvre
L5
Result of 5th manoeuvre
L6
Result of 6th manoeuvre
L7
Result of 7th manoeuvre
L8
Result of 8th manoeuvre
Description
Adjusts the pause time, i.e. time before
automatic re-closure. Applied only when
automatic closure function is enabled
Sets the sequence of commands
associated with the SS input or the 1st radio
command.
Sets the motor speed during normal travel.
Selects the device connected to the FLASH
output.
Sets the system for controlling motor force,
to adapt it to the weight of the door during
the opening manoeuvre.
Sets the system for controlling motor force,
to adapt it to the weight of the door during
the closing manoeuvre.
Controls the number of manoeuvres
after which the automation maintenance
notification signal is sent (see par. 10.1 -
"Maintenance notification").
Enables the user to check the type of faults
occurring in the last 8 manoeuvres (see par.
10.5 - "Fault log list").