1.3

TECHNICAL FEATURES

GG BT
Heat output
Nominal
Reduced
Heat input
Nominal
Reduced
Thermal yield 100% useful
Thermal yield useful at 30% of load
Termal efficiency (CEE 92/42 directive)
Losses after shutdown to 50°C (EN 483)
Supply voltage
Adsorbed power consumption
Electrical protection grade
C.H. setting range
Water content boiler
Maximum water head
Maximum temperature
Capacity of the heating expansion vessel
Pressure of the heating expansion vessel
D.H.W. setting range
D.H.W. flow rate (EN 625)
Continuous D.H.W. flow rate ∆t 30°C
Minimum D.H.W. flow rate
D.H.W pressure min/max
D.H.W. pressure min. nom. power
Smokes temperature min/max
Smokes flow min/max
CE certification
Category
Type of appliance
NOx emission class
Weight when empty
Main burner nozzle
Quantity nozzles
Nozzle diameter G20
Nozzle diameter G30/G31
Gas consumption *
Natural gas (G20)
LPG (G30/G31)
Burner gas pressure min/max
Natural gas (G20)
Butane (G30)
Propane (G31)
Gas supply pressure
Natural gas (G20)
Butane (G30)
Propane (G31)
* Gas consumption figures express the lowest calorific power of pure gas under standard conditions at 15°C – 1013 mbar; this figure may differ from the actual
figure, which is dependent on gas composition and environmental conditions.
25 OF
kW
22.8
kW
8.5
kW
25.0
kW
10.0
91.3
89.9
W
189
V-Hz
230-50
W
85
IP
X4D
°C
40÷80
l
2.9
bar
3
°C
85
l
8
bar
1.2
°C
10÷60
l/min
10.9
l/min
10.9
l/min
2.0
bar
0.2/7
bar
0.3
°C
83/110
g/s
18/19
No.
1312BT5260
II
2H3+
B
11BS
3 (< 150 mg/kWh)
kg
26
13
mm
1.30
mm
0.72
m
3
/h
2.61
kg/h
1.96
mbar
1.6/9. 1
mbar
4.6/27.7
mbar
4.6/35.7
mbar
20
mbar
28–30
mbar
37
25 BF
23.7
7.5
25.5
9.2
93.0
92.0
73
230-50
110
X5D
40÷80
2.9
3
85
8
1.2
10÷60
11.3
11.3
2.0
0.2/7
0.4
100/125
16/16
1312BT5261
II
2H3+
B
/C
22P-52P
12-32-42-52-62-82
3 (< 150 mg/kWh)
30
11
1.30
0.80
2.70
2.01
1.9/13.5
3.7/27.9
3.7/35.9
20
28–30
37
30 BF
28.0
9.0
30.0
10.8
93.3
92.0
87
230-50
115
X5D
40÷80
2.9
3
85
8
1.2
10÷60
13.0
13.4
2.0
0.2/7
0.3
100/125
18/18
1312BT5261
II
2H3+
B
/C
22P-52P
12-32-42-52-62-82
3 (< 150 mg/kWh)
31
13
1.30
0.78
3. 1 7
2.37
1.9/13.2
4. 1 /26.8
4. 1 /34.8
20
28–30
37
67
IT
ES
ENG

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gg bt 25 ofGg bt 30 ofGg bt 25 bfGg bt 30 bf