Climit GG BT Serie Manual Del Usuario página 88

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.3
DISASSEMBLING THE SHELL
(fig. 21)
The casing may be removed completely to
facilitate boiler maintenance, as shown in
fig. 21. Turn the panel control forward for
access to the internal components of the
boiler.
4.4
MAINTENANCE
To guarantee functioning and efficiency of
the appliance, in respect of the legal pro-
visions in force, it must be regularly
checked; the frequency of the checks
depends on the type of appliance and the
installation and usage conditions.
In any case, it should be inspected at
least once a year by a qualified technician.
88
Carry out the cleaning of the generator in
the following way:
– Turn the main switch off to stop electric
power reaching the boiler and close the
gas feed cock.
– Remove the outer casing and the gas
burner manifold unit. To clean the burner,
blow in a jet of air, so as to remove any
dust particles that may have accumula-
ted.
– Clean the heat exchanger, removing any
dust or residue from combustion. When
cleaning the heat exchanger or the bur-
ners, chemical products or steel bru-
shes MUST NOT BE USED.
Make sure that the tops of the burners
with the holes are free from encrusta-
tions.
– Reassemble the items removed from
the boiler, making sure to follow the cor-
rect sequence.
4 x
– Check operation of the main burner.
– After assembly of all the gas connec-
tions, these must be tested for sound-
ness, using soapy water or appropriate
products. DO NOT USE NAKED FLAMES.
– Do not use calcium chloride to treat the
plastic component during generator
maintenance.
4.4. 1
Chimney sweep function
To check boiler combustion, press at the
same time the installer's key (
a few seconds.
The chimney sweep function will switch on
and will continue for 15 minutes. During the
15 minutes functioning of chimney sweep
function, pressing the keys (
take the boiler respective at maximum (Hi)
and at minimum (Lo) power. From that
1
Codice/Code 8107960
Modello/Model CLIMIT GG BT 25 BF
Matricola/Serial n. 9999999999
PAR 1 = 01 (METANO)/ 03 (GPL)
PAR 2 = 01
2
e
) for
and
)
Fig. 21

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gg bt 25 ofGg bt 30 ofGg bt 25 bfGg bt 30 bf