English
ELECTRONIC CONTROL UNIT WITH 4 LIMIT SWITCHES FOR AUTOMATION
OF ONE OR TWO MOTORS FOR SWING GATES or SLIDING GATES
Technical characteristics
Power supply
No. of motors
Flashlight
Photocell power supply
Electric lock
Courtesy light
Operating temperature
General
The GiBiDi F4PLUS electronic control unit for automation of motors for swing gates or sliding gates is in conformity with the directives in force.
It offers a complete operating range (condominium, step-by-step, step-by-step with automatic reclosing, pedestrian gate, water hammer) and
adjustment functions (run time, pause time, phase shift and motor power).
It is versatile because of its options (4 limit switches, pre-flashing, flashlight controlled by control unit, courtesy light, cut-out of unused
inputs with dip switches, built-in or plug-in radio).
Easy to install thanks to the control LEDs (red for the safety switches = NC contacts, yellow for the controls = NA contacts); the extractable
terminal boards and the silk-screen printing on the printed circuit indicating connections and functions.
Installation notes
A )
Before proceeding with installation, a magnetothermal or differential switch with a maximum capacity of 10A must be fitted upstream of
the system. The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3 mm
B )
Differentiate and keep the power cables (minimum cross-section 1.5mm2 ) separate from the signal cables which may be 0.5mm2.
C )
Make the connections referring to the following table and the attached screen print. Be very careful to connect in series all the devices
that are connected to the same NC (normally closed) input and in parallel all the devices that share the same NA (normally open) input.
Connections (terminal board legend)
Output - OPENS motor 1
1
(motor to be used for pedestrian gate)
COMMON output - motor 1
2
(motor to be used for pedestrian gate)
Output - CLOSES motor 1
3
(motor to be used for pedestrian gate)
4
Output – OPENS motor 2
5
COMMON output - motor 2
6
Output – CLOSES motor 2
IF DIP 9 OFF = PHASE output for COURTESY LIGHT
7
(+3 minutes after run time) IF DIP 9 ON= Fixed output
for FLASHLIGHT code 70106
IF DIP 9 OFF = NEUTRAL output for COURTESY LIGHT
8
(+3 minutes after run time) IF DIP 9 ON= Fixed output
for FLASHLIGHT code 70106
9
LINE INPUT 230 V ~ NEUTRAL
1 0
LINE INPUT 230 V ~ PHASE
1 1
GROUND
1 2
GROUND
1 3
COMMON for FA1-FC1-FC2-FA2- inputs of PHOTOCELL
1 4
LIMIT SWITCH input - closes motor 2 (NC)
The motor capacitor is connected between terminals 1-3 (Motor 1) and 4-6 (Motor 2).
* If the system controls a double-gate system with phase shift (V3 turned clockwise), motor 1 starts opening two seconds before motor 2,
*
while during closing it starts the mouvement with the delay set by adjusting trimmer V3.
AUTOMATISMI PROFESSIONALI PER CANCELLI E GARAGE
230 Vac, single-phase, 50/60 Hz
2 x 0.5 HP max.
230 Vac 40W max
24 Vac, 8W max. (2 pair of photocells+radio)
12 Vac 15W max.
230 Vac, 100W max.
-20 +55 °C
*
1 5
1 6
*
1 7
*
1 8
1 9
2 0
2 1
2 2
2 3
2 4
2 5
2 6
2 7
2 8 / 2 9
6
LIMIT SWITCH input-opens motor 2 (NC)
LIMIT SWITCH input-closes motor 1(NC)
LIMIT SWITCH input-opens motor 1 (NC)
PHOTOCELL input (NC)
START input (NO)
24 Vac output for power supply of PHOTOCELLS and
ACCESSORIES (max. 8W) (2 pair of photocells + radio re c e i v e r )
Common output (0 Vac) for power supply of
PHOTOCELLS, ACCESSORIES and ELECTRIC LOCK
12 Vac output for ELECTRIC LOCK (max. 15W)
STOP input
(NC; if not used connect with jumper to terminal 25)
Input for PEDESTRIAN GATE STA RT (NA, acts on motor 1)
COMMON input for STOP-START-START PEDESTRIAN
GATE
ANTENNA BRAID input
ANTENNA CORE input
Relay clean-contact to:
connect a flashlight with fixed light (code 70107)
-
drawing power from the terminals 7 and 8 (the relay
flashes fast during opening and slowly during closing).
control a warning light to signal gate movement.
Connect a 24 Vac lamp powered by terminals 20-21
-
(max. 1Watt)